Whirlpool GR556LRKB0 installation instructions Direct wire method, Four-wire electrical connection

Page 5

Four-wire electrical connection:

Use this method for new installations, mobile homes, recreational vehicles, and whenever four-wire installation is required.

7.Remove the ground-link screw from the range frame. Save the ground- link screw. Bend up the ground link so that it does not contact the range.

 

ground-link

ground link

screw

8.Connect the green ground wire from power supply cord to the range using the ground-link screw. The ground wire must be attached first and must not contact any other terminal.

ground- link screw

green ground wire

Three-wire electrical connection:

silver-colored terminal block screw

 

 

 

line 2

 

ground

 

 

 

 

neutral

link

 

 

(center

 

 

 

wire)

 

 

 

 

 

 

 

 

 

line 1

U.L.-listed strain relief

 

 

and 40 amp range power

 

 

supply cord

Use this method only if local codes permit connecting cabinet-ground conductor to neutral wire of power supply cord.

7.Use the brass terminal nuts attached to the terminal block cover to connect the neutral wire (center wire) to the silver-colored terminal screw on the terminal block.

8.Connect the other two wires to outer terminal screws on the terminal block.

9.Do not loosen factory-installed nuts already on the terminal. Tighten nuts with 3/8" nut driver for proper electrical connection.

10.Tighten the strain relief screws.

11.Reinstall the terminal block cover.

supply cable. Depending on your electrical supply, make the required three-wire or four-wire connection.

1.Disconnect power.

2.Remove the knockout for the power supply cable.

3.Assemble a U.L.-listed conduit connector in the opening.

U.L.-listed conduit connector

4.Strip the insulation back 1 inch from the end of each wire.

1"

5.Allow enough slack in the wire to easily attach the wiring to the terminal block.

6.Use 3/8" nut driver and remove the outside nuts on the terminal block screws. Do not loosen the factory- tightened nuts behind the outside nuts.

7.IMPORTANT: the aluminum lugs must be assembled to the terminal posts with the set screws facing out as shown.

9.Connect the neutral (center wire) wire to the center, silver-colored terminal screw on the terminal block using the brass nuts that are attached to the terminal block cover.

Direct wire method

NOTE: The bag containing three

aluminum lug

terminal screw

silver-colored terminal block screw

neutral wire (center wire)

green ground

wire

U.L. listed strain relief and 40 amp range

power supply cord

10.Connect the other two wires to the outer terminals on the terminal block.

11.Do not loosen the factory installed nuts already on the terminal. Tighten nuts with 3/8" nut driver for proper electrical connection.

12.Tighten the strain relief screws.

13.Replace the terminal block cover.

aluminum terminal lugs must be used when making a direct wire connection.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire, or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

This range may be connected directly to the fuse disconnect or circuit breaker box; or with a U.L.-listed, 40 amp range power

set screw must face out

8.Attach three aluminum lugs to terminal posts.

Use a 3/8" nut driver and tighten the nuts securely. Nuts must be tightened to 20 in/lbs of torque for proper electrical connection.

9.Complete electrical connection according to your type electrical supply (“Four-wire electrical connection” or “Three-wire electrical connection.”)

5

Image 5
Contents Installation Instructions Before you start Parts supplied for installation Tools and materials neededMobile home installation Product dimensions Cutout dimensions/requirementsAnti-tip bracket Electrical requirementsNot used for Canadian installations Power supply cord methodIf connecting to a Four-wire electrical system If connecting to a Three-wire electrical systemThree-wire electrical connection Direct wire methodFour-wire electrical connection With range in kitchen Now start…12.The If you need service For cleaning MaintenanceIf you need assistance If range does not operateInstructions d’installation Avant de commencer Outillage nécessaire pour l’installationInstallation dans une résidence mobile Bride antibasculement Dimensions de la cavité d’installation Dimensions du produitÉlectrique à 3 conducteurs Raccordement à un circuit Électrique à 4 conducteursCommencer maintenant… MED Si une intervention de réparation est nécessaire Si une assistance est nécessaire