9.Grasp the edges of the oven door with both hands and close the oven door until it will no longer close. Lift and pull oven door toward you and remove. Set the oven door aside on a protective surface.
10.Side trims are located on the side of the unit. Side trims must be removed before unit is installed in the cabinet. Remove the cable ties from the side of the unit.
Make Electrical Connection
WARNING
Electrical Connection Options Chart
If your home has: | Go to section: |
| Power Supply |
| ½" |
| (1.3 cm) |
| Power Supply |
½"
(1.3 cm)
4-Wire Cable from Home Power Supply
IMPORTANT: Use the
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death, fire, or electrical shock.
This oven is manufactured with a neutral (white) power supply wire and a
1. Disconnect power. |
A
B
C
D
A. Cable from home power supply B. Black wires
C. Red wires
D.
E
F
G
H
I
F. White wires
G. UL listed wire connectors H. Green (or bare) ground wires
I. UL listed or CSA approved conduit connector
2. | Feed the flexible cable conduit from the oven through the |
| opening in the cabinet. |
3. | Remove junction box cover if it is present. |
4. | Install a UL listed or CSA approved conduit connector to the |
| junction box. |
A
A. UL listed or CSA approved conduit connector
5.Route the flexible cable conduit from the oven to the junction box through a UL listed or CSA approved conduit connector.
6.Tighten screws on conduit connector.
7.See “Electrical Connection Options Chart” to complete installation for your type of electrical connection.
1.Connect the 2 black wires (B) together using a UL listed wire connector.
2.Connect the 2 red wires (C) together using a UL listed wire connector.
3.Untwist white wire from green (or bare) ground wire coming from the oven.
4.Connect the 2 white wires (F) together using a UL listed wire connector.
5.Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL listed wire connector.
6.Install junction box cover.
6