Broan QTR100 warranty Install Housing & Duct Connect Wiring

Page 3
I-JOIST

 

 

 

MODEL qtr100

 

 

 

 

 

 

 

 

 

 

 

Page 

INSTALL HOUSING & DUCT

 

CONNECT WIRING

1.

Bend

 

 

housing

 

 

tabs.

 

 

Use a pliers to

 

 

bend housing

 

 

TABS out to 900.

TABS

 

 

2.

Mount

SPACER

 

housing to

 

(use for mounting to I-Joist)

 

joist.

 

Hold housing in place so that the housing tabs contact the bottom of the joist. The hous- ing mounts with four (4) screws or nails. Screw or

nail housing to joist through lowest holes in each mount- ing flange, then through highest holes. NOTE: Mounting to I-JOIST(shown) requires use of SPACERS (included) between the highest hole of each mounting flange and the I-joist.

3. Attach damper/duct connector.

Snap damper / duct connector onto housing.

Make sure con- nector is flush with top of housing and damper flap falls closed.

4.Install 4- inch round

ductwork.

Connect 4-inch round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork con- nections to make

them secure and air tight.

5. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use proper UL approved connector to secure house wiring to wiring plate. Connect wires as shown in wiring diagrams.

Image 3
Contents Operation Cleaning & MaintenanceWarranty Read and Save These InstructionsPlan the Installation Typical InstallationsInstall Housing & Duct Connect Wiring Finish ceiling Install GrilleService Parts Attach grille to housingLEA Y Conserve Estas Instrucciones Planificación DE LA Instalación Instalaciones TípicasInstale LA Cubierta Conexión Eléctrica EL Conducto Acople la rejilla a la cubierta Instale LA RejillaPiezas DE Repuesto Termine el cielo raso