Broan E662 installation instructions Prepare the Hood, Install the Hood

Page 7

5. PREPARE THE HOOD

5.1Remove filters from the hood. Remove (3) screws holding both side panels to the hood and set aside. Remove both side panels.

 

SCREW LOCATION

 

1

2

3

HO0042

5.2Punch out 2 knock-out holes for electrical connections (2 on top or one on top and one on back of the hood).

5.3Attach one wire clamp on top of the hood for the provided electrical cable with 3-prong plug. Through the wire clamp, insert this electrical cable in the hood and tighten the wire clamp to secure the cable.

5.4Connect cable wires as follow: BLUE wire with red connector to BLUE wire with red connector (A), BROWN wire with red connector to BLACK wire with red connector (B), GREEN wire under ground screw (C).

DO NOT FORGET TO CONNECT THE GROUND.

6. INSTALL THE HOOD

B

A

C

HE0052

6.1Run power cable to installation location. Position the hood in its intended location. Using a pen mark the position of the screws (smaller part of the keyholes, see pictures below for the (5) keyholes locations). Remove the hood.

6.2Install (4) no. 8 x 1/2” screws, leaving a 1/8” gap (do not install the no. 5 screw yet).

1

2

HD0127

5

3

1

 

2

4

HD0129

3

4

HD0128

- 7 -

Image 7
Contents Model E662 To Reduce the Risk of a Range TOP Grease Fire Table of Contents Broan Elite E662 Hood System Prepare the Installation Install DuctworkCutting Holes Cabinet PreparationPrepare the Hood Install the HoodCabinet Blower Preparation Install the Hood CONT’DALL Discharge Types Install the Blower in the CabinetReinstall Side Panels Connect WiringLight Bulbs Heat Sentry OperationUSE and Care Avoid when choosing a detergentGround Wiring DiagramService Parts Warranty