Cannon BHC110 Maintenance, Cleaning the hood, Cleaning the grease filters, Replacing the lamps

Page 9

Maintenance

!Always switch off the electricity supply before carrying out any cleaning or servicing operations on the appliance.

!To avoid possible risks of fire always comply with the indicated instructions when cleaning grease filters and when removing grease deposits from the appliance.

Careful maintenance will assure good functioning and good efficiency over time.

Cleaning the hood

Any fat deposits should be removed from the appliance periodically depending on amount of use (at least every 2 months). Avoid using abrasive or corrosive products. To clean painted appliances on the outside, use a cloth dipped in lukewarm water and neutral detergent. To clean steel, copper or brass appliances on the outside, it is always best to use specific products, following the instructions on the products themselves. To clean the inside of the appliance, use a cloth (or brush) dipped in denatured ethyl alcohol.

Cleaning the grease filters

To remove the grease filters, turn the panel by gripping it from the front part of the hood; remove the grease filters by pushing the catch towards the rear of the hood and turning the filters outwards.

Wash the filters by hand or in the dishwasher using a neutral detergent. If they are washed

in the dishwasher, any loss of colour will

not jeopardise functioning of the filters in any way.

Clean the grease filters every 2 months on average depending on how heavily the hood is used.

Replacing the charcoal filter

GB

 

If using the hood in the filtering version, the charcoal filter (P) will periodically have to be replaced.

First of all, turn the panel and remove the metal grease filters. Push the catch towards the inside and remove the charcoal filter from its seat.

Replace the charcoal filter with one of the same type by carrying out the operations in reverse order.

Replace the charcoal filter on average every 6 months depending on how heavily the hood is used.

Replacing the lamps

Pay particular ATTENTION when carrying out

this operation and remember to remove the voltage. To replace the halogen lamps, open the cover by prising in the slots. Replace with lamps

of the same type.

WARNING: Do not touch the new lamp with bare hands.

9

Image 9
Contents Art of Cooking Page Instructions for use BHC 90 BHC ContentsAssembly InstallationFixing to the wall Securing the decorative flueFiltering version Ducting versionPower cable Technical data Technical informationElectrical connection Description Filtering versionDucting version Controls OperationCleaning the hood MaintenanceCleaning the grease filters Replacing the lampsGeneral safety Precautions and tipsDo not place weights above the hood DisposalPage Key Contacts

BHC110, BHC90 specifications

Cannon is known for its innovative and high-performance products in the world of heating and cooling systems, and the BHC90 and BHC110 are prime examples of this legacy. These gas condensing boilers are designed to cater to both residential and commercial heating needs, delivering efficiency and reliability.

The Cannon BHC90 has a maximum output of 90 kW, while the BHC110 boasts a higher capacity of 110 kW. Both models are engineered to provide optimal heating solutions, making them suitable for various applications, from small residential settings to larger commercial spaces. The compact design of these boilers allows for easy installation and integration into existing systems, saving valuable space without compromising on performance.

One of the standout features of the BHC series is the incorporation of advanced condensing technology. This technology allows the boilers to recover heat from exhaust gases, utilizing it to pre-heat incoming water. As a result, the systems achieve remarkable seasonal efficiencies, significantly reducing energy consumption and operating costs. The BHC90 and BHC110 can achieve efficiency ratings of up to 109%, an impressive benchmark in the industry.

In terms of user experience, both boilers are equipped with a user-friendly digital control interface. This feature allows homeowners and facility managers to monitor and adjust heating settings easily. Additionally, both models support compatibility with modern building management systems, providing seamless integration for enhanced operational control.

The BHC series also prioritizes safety and durability. They are designed with robust materials and advanced safety systems, including flame monitoring and pressure relief valves, ensuring reliable and worry-free operation. Their low NOx emissions contribute to reduced environmental impact and compliance with stringent regulations.

Maintenance is simplified with easy access to key components, ensuring that service and repairs can be conducted with minimal downtime. This longevity and reliability make the Cannon BHC90 and BHC110 excellent choices for those seeking efficient, high-capacity gas condensing boilers. Overall, the combination of advanced technologies, user-friendly features, and commitment to sustainability positions the Cannon BHC90 and BHC110 as leaders in the heating market.