CFM Corporation PVS-1 manual Mount Power Venter, Vertical Mounting

Page 6

Majestic® Fireplaces Power Venting System

18” (457mm)

Minimum

FP1421

Fig. 5 An 18” (457mm) minimum vertical rise is necessary before a 90° elbow.

Incorrect

Correct

FP1423

 

 

4.Install optional sound reducer (Model SR5 or SR4) onto fireplace. See Installation Instructions pack- aged with sound reducer.

5.Mount Power Venter

NOTE: It is best to locate the fan near the vent terminal. However, if such a location is not suitable, the fan can be installed anywhere within the vent system.

a.Remove vibration isolation mount and retain the nut from the parts bag and install. Install on Power Venter as shown in diagram. Next install flexible duct piece and outlet collar using four (4) screws to fasten.

b.To prevent vibration, securely support Power Venter from ceiling or joist with Power Venter bracket. (Fig. 8)

c.By using 1” (25 mm) bracket, clearance to fan is maintained at 1” (25 mm). The addition of the 6” (152 mm) bracket, maintains a 6” (152 mm) clear- ance to combustibles.

Vertical Mounting

Fig. 6 Vent pipe transitions should be gradually tapered.

Power Venter

 

Negative Pressure

Positive Pressure

 

All seams on the positive side of power venter to be sealed with high temperature silicone sealant.

Ceiling

6” (152 mm) Bracket

1” (25 mm) Bracket

Vibration

Isolation

Mounts

Fan

FP1424

Power Venter

Bracket

Discharge

Power Venter

FP1422

Fig. 7 Vent pipe connections and all joints on the outlet side of the power venter must be sealed with high temperature sealant.

Installation

1.

Cut 6¹⁄₄” (159mm) diameter hole through outside wall

 

- see General Code Requirements for proper loca-

 

tion.

2.

Install vent terminal. Fasten from outside with four

 

(4) screws and caulk around flange edge.

Horizontal Mounting

Wall or

Wall

Studs

Discharge

Fan

3. Locate fireplace and fasten to floor as shown in fire-

place manual.

Power Venter Bracket

FP1425

Fig. 8 Power venter mounting options.

6

51810

Image 6
Contents Power Venting System Model PVS-1 Installation Instructions Power Vent System Parts and DescriptionGeneral Venting Information Vent System Termination Power Venter SpecificationsGeneral Code Requirements Location of the FanCanadian Installations1 US Installations2 General Venting Information Termination LocationInstallation Installation RestrictionsMount Power Venter Vertical MountingElectrical Wiring Operation Sequence of 24 VAC Controlled ApplianceMaintenance Operation and Checking the DraftPoints of inspection are Power Venter Part List Pressure Switch Power Venter Motor LeadsMajestic Fireplaces Power Venting System Majestic Fireplaces Power Venting System CFM Corporation