Blanco BCGC74 - BCGC52 warranty Location and Ventilation, GAS Connection, Natural Gas

Page 7

INSTALLATION

5) LOCATION AND VENTILATION

Ventilation must be in accordance with AS5601/AG601–GasInstallations.

In general, the appliance should have adequate ventilation for complete combustion of gas, proper flueing and to maintain temperatureofimmediatesurroundingswithinsafelimits.

The wall and bench surfaces must be capable of sustaining temperaturesof75°C.

All laminates, fixing adhesive and surfacing materials should becertifiedsuitableforthistemperature.

6) GAS CONNECTION

This gas connection is male 1/2” BSP and is situated at the rear of the appliance, 415 mm from the right hand side and 55 mm from the rear of the cooktop.

A. The hotplate can be connected with rigid pipe as specified in AS5601 table 3.1.

B. If installing with a hose assembly, install with a hose assembly that complies with AS/NZS 1869 (AGA Approved), 10mm ID, class B or D, no more than 1.2m long and in accordance with AS5601. Ensure that the hose does not contact the hot surfaces of the hotplate, oven, dishwasher or any other appliance that may be installed underneath or next to the hotplate. The hose should not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its entire length with the cooktop in the installed position.

Unions compatible with the hose fittings must be used and all connections tested for gas leaks.

The gas supply connection for the hose assembly must be accessible.

Natural Gas

Natural Gas installations require the connection of a gas regulator at the appliance. This regulator is supplied with the appliance on purchase.

Assemble the regulator (noting the gas flow direction) and transition pieces (supplied with the appliance), in accordance with figure 10.

The transition piece on the supply side of the regulator must be provided by the installer.

The appliance is factory set for Natural Gas. The test point pressure should be adjusted to 1.00 kPa with the wok burner operating at maximum.

Liquified Petroleum Gas

In a Universal LPG installation the gas regulation is made at the gas cylinder and regulation at the appliance is not required. The supply pressure should be 2.75 kPa. To connect supply to the appliance use transition pieces as shown in figure 11. These pieces are supplied with the appliance on purchase.

WARNING:

THE BURNER FLAME MUST BE ADJUSTED BY THE INSTALLER.

FAULTY INSTALLATION WILL NOT BE COVERED UNDERWARRANTY.

FIG. 10

FIG. 11

7

Image 7
Contents Models BCGC74 BCGC52 Crystal Glass Cooktop Natural Description of the HOT PlatesLPG USE HOW to USE the BurnersBurners Air inlet minimum cm2 Preventative Maintenance CleaningHOT Plate Overall Dimensions 680 x 500 mm InstallationInstalling the HOT Plate Comply with the DimensionsLiquified Petroleum Gas Location and VentilationGAS Connection Natural GasBefore Leaving Electrical ConnectionTheappliancemustbeearthed Data LabelReduced rate adjustment AdjustmentsTaps Burner Main injector LPG to Natural GAS Conversion ProcedureNatural GAS to Universal LPG Conversion Procedure ConversionsBurner Arrangement on the HOT Plate Servicing Components ReplacementGreasing the taps see Cable Types and Sections MEA Blanco Technical Assistance and Spare Parts Technical Assistance and Spare Parts

BCGC74 - BCGC52 specifications

The Blanco BCGC74 and BCGC52 are two high-performance gas cooktops that stand out in the realm of kitchen appliances, offering modern technology and features that cater to both professional chefs and home cooks alike. Both models are designed with user convenience and efficiency in mind, making cooking a seamless experience.

The Blanco BCGC74 features a sleek design with four powerful burners, providing flexibility for various cooking techniques. It offers a combination of high-output burners and simmer burners, allowing users to boil, fry, and simmer with precision. The BCGC52, on the other hand, has a slightly more compact design with two efficient burners, perfect for smaller kitchens or for those who prefer a minimalist setup without sacrificing performance.

One of the most notable aspects of these cooktops is their advanced ignition system. The automatic ignition ensures that the burners light up effortlessly with a simple twist of the knob, eliminating the need for matches or manual lighting. This feature not only enhances safety but also promotes ease of use for all levels of cooks.

In terms of materials, both models are constructed with high-quality stainless steel, ensuring durability and easy cleaning. The smooth surface is resistant to stains and scratches, maintaining a polished look even after extensive use. Additionally, the burners are designed to deliver even heat distribution, promoting consistent cooking results across the entire surface.

Safety is a paramount consideration in the design of the Blanco BCGC74 and BCGC52. Both models are equipped with flame failure devices that automatically shut off the gas supply if the flame goes out, preventing potential hazards. This feature provides peace of mind for users, especially in households with children.

Another key characteristic of these cooktops is their ergonomic control knobs. The knobs are strategically placed for easy access, allowing for precise temperature adjustments without hassle. This user-friendly design enables cooks to focus on their culinary creations rather than struggling with controls.

Moreover, the Blanco BCGC74 and BCGC52 are compatible with a variety of cooking accessories such as griddles and wok pans, making them versatile additions to any kitchen. Overall, the Blanco BCGC74 and BCGC52 gas cooktops blend modern technology with practical design features, enhancing the cooking experience while ensuring safety and efficiency.