Amana UXT5536AA specifications Product Model Numbers, Venting Requirements, Location Requirements

Page 1

Range Hood - 30" (76.2 cm) and 36" (91.4 cm)

PRODUCT MODEL NUMBERS

UXT5530AAUXT5536AA

Electrical: A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range hood be provided.

CABINET OPENING DIMENSIONS

C

B

D

A

PRODUCT DIMENSIONS

 

 

1³⁄₁₆"

12"

 

(3.0 cm)

 

 

(30.5 cm)

 

 

7¹⁄₄"

 

(18.4 cm)

3" (7.6 cm) -

2"

⁵⁄₈"

30" (76.2 cm) model

(1.6 cm)

5³⁄₄" (14.6 cm) -

(5.1 cm)

 

36" (91.4 cm) model

9"

 

 

 

(22.9 cm)

 

 

 

⁵⁄₈"

 

 

(1.6 cm)

 

29 ⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model

 

19³⁄₄"

 

 

(50.2 cm)

 

35 ⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model

 

 

 

 

 

VENTING REQUIREMENTS

Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10" (8.3 x 25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that gently reduce performance.

E

A. 18" (45.7 cm) min. clearance - upper cabinet to countertop

B. 24" (61.0 cm) min. for electric cooking surfaces 27" (68.6 cm) min. for gas cooking surfaces

30" (76.2 cm) suggested max. - bottom of range hood to cooking surface

Roof Venting

A

E

B

 

C

 

D

 

Wall Venting

A

 

B

E

C

 

D

 

C. 30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width D. 13" (33.0 cm) cabinet depth

E. 36" (91.4 cm) base cabinet height

LOCATION REQUIREMENTS

IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.

Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.

A. 6" (15.2 cm) or larger round vent or a 3¹⁄₄" x 10" (8.3 x

25.4 cm) rectangular vent through roof

B.Round vent: use 6" (15.2 cm) or larger round damper (purchased separately)

C.Round vent: use 3¹⁄₄" x 10"

(8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece

(purchased separately)

D.24" (61.0 cm) - 30" (76.2 cm) above electric cooking surface 27" (68.6 cm) - 30" (76.2 cm) above gas cooking surface

E.Roof cap

A. 6" (15.2 cm) or larger round vent or a 3¹⁄₄" x 10" (8.3 x

25.4 cm) rectangular vent through the wall

B.Round vent: use 3¹⁄₄" x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)

C.3¹⁄₄" x 10" (8.3 x 25.4 cm) through the wall

D.24" (61.0 cm) - 30" (76.2 cm) above electric cooking surface 27" (68.6 cm) - 30" (76.2 cm) above gas cooking surface

E.Wall cap

Page 1 of 2

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.