Aprilaire 8100 manual Mechanical Installation, Wall Mount

Page 4

MECHANICAL INSTALLATION

WALL MOUNT

The unit can be mounted on a concrete wall or on a stud wall.. The mounting bracket is pre-drilled for fastening to standard 16” O..C.. or 24” O..C.. stud spacing.. Remove the access panel, EnergyMax Transfer Core, and air filters for installation..

1.Remove the access panel, EnergyMax Transfer Core and filters.. (See Figure 4..)

2.For Stud Wall: Fasten the supplied mounting bracket to the wall using the supplied lag bolts and washers.. (See Figure 5..)

For Concrete Wall: Fasten the supplied mounting bracket to the wall using field supplied concrete anchors and the supplied lag bolts and washers..

3.Insert the supplied hanging pin in the left hole of the mounting bracket and secure by inserting the supplied washer and hand tightening with the supplied nut.. (See Figure 5..)

4.Insert the supplied hanging pin in the right hole of the mounting bracket.. (See Figure 5..)

5.Fasten the hanging hook bracket to the left side of the unit with the supplied 10-32 x 3/8” machine screws, using the pre-tapped holes along the side of the unit.. (See Figure 6..)

6.Fasten the supplied hanging hinge bracket to the right side of the unit with the supplied 10-32 x 3/8” machine screws, using the pre-tapped holes along the side of the unit.. (See Figure 6..)

7.Pick the unit up and hook the hanging hook bracket on the left hanging pin.. (See Figure 7..) Note: Keep pressure against the unit to prevent it from swinging away from the wall.

8.Push the unit against the bracket, remove the right side pin, align the hanging hinge hook with the bracket and reinsert the hanging pin.. Secure the pin by inserting the supplied washer and tightening the supplied nut.. (See Figure 8..)

9.Securely tighten the nut on the left side of the unit..

10.Reinstall the EnergyMax Transfer Core, air filters and access panel..

Figure 4 – Removing Core and Filters

ENERGYMAX

TRANSFER CORE

FILTER

FILTER

90-1741

Figure 5 – Installing Mounting Bracket on Wall

HANGING PIN

HANGING PIN

MOUNTING BRACKET

LAG BOLT

AND WASHER

THREADED NUT

WASHER

90-1735

 

Figure 6 – Installing Mounting Brackets

 

 

 

 

 

MACHINE SCREWS

 

 

 

HINGE BRACKET

HOOK BRACKET

 

HINGE BRACKET

 

(hook points out)

 

 

 

(hinge points out)

 

 

 

 

 

 

MACHINE SCREWS

 

LEFT END

RIGHT END

HOOK BRACKET

90-1734

 

 

 

 

 

Figure 7 – Hanging Left Side of ERV

 

HANGING

MOUNTING

PIN

BRACKET

HOOK BRACKET

 

HINGE BRACKET

 

 

90-1742

4

 

Figure 8 – Hanging Right Side of ERV

HANGING PIN

MOUNTING BRACKET

HINGE BRACKET

WASHER

THREADED NUT

90-1736

Image 4
Contents Safety Instructions Table of ContentsUnpacking and Contents Dimensions and Location Considerations Location ConsiderationsMechanical Installation Wall MountMechanical Installation Ceiling MountDuct work Specifications GrillE and Hood SpecificationsDucting Duct work Connections ForceD Air SystemSupply Fresh Air From ERV to House Return From Living Space to ERVOutdoor Exhaust and Fresh Air Connections Balancing the System Duct work Connections Without Forced AirEquipment Required Before balancing the system, verify the followingBalancing the System Balancing AirflowAirflow Approximations GaugeConstant On Operation System START-UPOperation With Home Comfort Control Figure System START-UP Cycle Time Setting minutesVentilation Air Requirements, CFM Troubleshooting Guide TroubleshootingSymptom Possible Reason Troubleshooting Procedure
Related manuals
Manual 5 pages 5.65 Kb

8100 specifications

The Aprilaire 8100 is a high-performance dehumidifier designed to create a healthier and more comfortable home environment. This energy-efficient solution effectively removes excess moisture from the air, helping to prevent the growth of mold, dust mites, and other allergens while also protecting your home from potential damage caused by humidity.

One of the standout features of the Aprilaire 8100 is its impressive capacity to dehumidify large areas. With the ability to remove up to 90 pints of moisture per day, this unit is ideal for basements, crawl spaces, and other areas where humidity levels can become unmanageable. This capability allows homeowners to maintain optimal humidity levels, typically between 30% and 50%, which contributes significantly to improved indoor air quality.

The Aprilaire 8100 is equipped with the latest in dehumidification technology. It utilizes a high-efficiency compressor and an enhanced air filter system that traps airborne particles, ensuring cleaner air circulation. The unit operates quietly, making it suitable for use in living spaces without disruptive noise.

One of the defining characteristics of the Aprilaire 8100 is its built-in Smart Technology. This includes a digital control panel that enables users to set their desired humidity levels easily. The unit also features automatic humidity sensing, allowing it to adjust its operation based on current conditions. This not only enhances comfort but also leads to energy savings, as the system only runs when necessary.

Another advantage of the Aprilaire 8100 is its low-maintenance design. The unit features a washable pre-filter and a self-draining reservoir, which minimizes the need for frequent upkeep. Additionally, the durable construction ensures that this dehumidifier will last for years, providing reliable performance throughout its lifespan.

In summary, the Aprilaire 8100 dehumidifier stands out with its powerful moisture removal capacity, cutting-edge technology, and user-friendly features. It is a versatile solution for maintaining a healthy indoor environment, making it an essential appliance for homeowners looking to combat humidity and improve air quality. Its efficiency, ease of use, and low-maintenance design make it a worthwhile investment for any household.