Wadia Digital 931921 operation manual Standard Configuration

Page 7

series 9 DecodingComputer System

Standard Configuration:

Step 1: Connect data output 1 from the Wadia 931 Digital Controller to the data input of the left channel Wadia 921 Mono Decoding Computer.

Step 2: Connect ClockLink output 2 from the Wadia 931 Digital Controller to the ClockLink input of the left channel Wadia 921 Mono Decoding Computer.

Step 3: Connect data output 3 from the Wadia 931 Digital Controller to the data input of the right channel Wadia 921 Mono Decoding Computer.

Step 4: Connect ClockLink output 4 from the Wadia 931 Digital Controller to the ClockLink input of the right channel Wadia 921 Mono Decoding Computer.

6

Image 7
Contents Information&OperationManual 931/ 921DecodingComputerSystem Quick Start Table of Contents PreliminariesInstallation and Set-up Operation and ConfigurationBrief History Thank YouOverview How to Use this ManualInventory Operation Quick Start Unpacking and PlacementLevel Setting ConnectionsStandard Configuration Installing the Tip-Toes Installation and Set-up UnpackingPlacement AC PowerConnecting the Wadia 931 to a Digital Source Wadia Digital Sources with ClockLink Wadia 921 Decoding Computer Inputs Connecting the 931 Wadia 931 Digital Controller OutputsConnecting to 921 Mono Decoding Computers Powering up Connecting to Wadia 921 Mono Decoding ComputersConnecting Directly to an Amplifier Connecting to a PreamplifierIlluminated Status Indicator Choosing a Digital Cable Should I use a Balanced or Unbalanced connection? Why should I bypass the Preamplifier?Does the Wadia Volume Control compromise resolution? Can I bypass the Wadia Volume Control?Front Panel Controls Table of Wadia 931 Digital Controller Remote Functions Wadia 931 Remote Control CommandsOperational Screens Status Screen Direct Access to Operational ScreensBalance Screen Ba la n ce F tNo Data Volume and InputMute Mut Cal L ass PtiEmphasis Detect Additional Features StandbyAss St andby Pt ic Sampling Rate DetectMenu Screen Map Configuration Entering Configuration ModeNavigating in Configuration Mode Configuration FunctionsConfiguration Menu Screen Map Configuring Input ClockLink On or Off Configuring InputsPu t 4 Clo ckli Nked Configuring Outputs Configure Input NameInpu Ame Xi al Ou tpu Oc k Le ft Ht O f f Hich Out p ut ? 3 4 5 6 7 8 Ex i tResto Facto Set Ngs Restoring Factory SettingsSaving Configuration Settings Exiting Configuration ModeSoftware License Agreement Appendices Troubleshooting Lock-upEnvironmental Care AES/EBU Technical SpecificationsSafety Precautions Warranty Www .wa d ia.co m