Wind Crest VEN150E installation instructions 1500 CFM

Page 1

Externally Mounted Ventilators – Install Quick Specs

VEN150E

Installation Type & Discharge Direction Mounted outside. Can be mounted on exterior roof or wall.

CFM Rating

1500 CFM

Minimum Duct Size

10” round

Maximum Equivalent Straight Duct Length 50 feet

Equivalent Straight Lengths

•1 foot of 8” or 10” duct = 1 foot

•1 foot of 3 ¼” x 14” rectangular = 1 foot

•8” round 90 degree Elbow = 5 feet

•10” round 90 degree Elbow = 3 feet

•Wall or Roof Cap = 2 feet

Standard Features

•Adaptable to all Wind Crest hoods

•Weather-resistant glavanized steel construction

•Thermally protected, permanently lubricated motor

•Dynamically balanced 12” diameter blower wheel

•Neoprene resilient anti-vibration mounted

•Built-in Flashing plate for roof or wall mount

•Easily removed blower cover for periodic cleaning

Ventilator Carton Weight:

VEN150E = 80 lbs.

7"

4"

 

 

"

24

0

3

 

"

 

 

 

VEN150E

UL LISTED 7Z66

C UL

Ventilator Motor Ratings*

Hoods without Heat Lamps:

12.0Amps @ 120 V AC, 60 Hz Hoods with Heat Lamps:

16.4Amps @ 120 V AC, 60 Hz

*20 Amps @ 120 V AC, 60 Hz required when using VEN150E ventilator.

Copyright 2006 Wind Crest by CNP Industries

1

Install Quick Specs are for planning purposes only. Please refer to the detailed installation instructions, prior to making any cutouts.

Image 1
Contents 1500 CFM VEN150EVEN150E Internally Mounted Ventilators Install Quick Specs