Safety instructions

through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors. E. This unit must be grounded.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

 

WARNING - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES

MAY

 

BE DANGEROUS.

 

A. Do not check filters with hood working.

 

B. Do not touch the lamps after a prolonged use of the appliance.

 

C. No food must be cooked flambè underneath the hood.

 

D. The use of an unprotected flame is dangerous for the filters and could

cause

fires.

 

E. Watch constantly the fried food in order to avoid the cooking oil flares up. F. before performing any mainteinance operation, disconnect the hood from the electrical service.

WARNING! For models AED-M90ASX and ADU-M90ASX never lean on the hood's body any object weighing more than 33,1lb (15kg), although evenly spread over the whole surface.

The manufacturers will not to accept any responsability for eventual damages, because of failure to observe the above instructions.

- 6 -

Image 6
Contents Range Hood Installation instructions AED M90ASXCappa Aspirante istruzioni per l’uso...Pag Contents InstallationPag Safety instructions Important Safety Instructions For Residential USE onlyPlease Read Entire Instructions Before Proceeding Installation Instructions MAY List of Materials Models ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWXModels ASU-M90ASX / ASU-E42ASX Models AED M90ASX Type DescriptionLight Panel Light Bulbs Ducting Calculation Sheet Maximum Duct LengthHood Specifications Models ASU-M90ASX / ASU-E42ASX Front of hood Side of hood Models AED-M90ASX Top of hood Side of hoodModels ADU-M90ASX Front of hood Top of hood Installation Internal Blower Hood is now ready to be installed on the wall Installation External & In-Line Blower Preparation Installation External & In-Line Blower Preparation Installation Ducting Options Installation Mounting the Range Hood Mounting HeightsMounting to the Wall General Installation Power Supply ConnectionPower Supply Connection Black = L lineInstallation Mounting the Duct Cover Mounting the Duct CoverModels ASU-M90ASX and ASU-E42ASX Maintenance MaintencanceDescription Hood PART# Replacement Parts Parts3LIK0482

ALA - M90ABX, ALA - E42AWX, ALA - M90AWX, ALA - E42ABX, AED - M90ASX specifications

The Zephyr ASU - M90ASX, ALA - E42ABX, ALA - M90ABX, ALA - M90AWX, AED - M90ASX represents a significant advancement in air separation technologies. Designed for efficiency and versatility, these models cater to a range of industrial applications that require reliable and cost-effective oxygen and nitrogen production.

One of the main features of the Zephyr ASU series is its modular design, allowing for easy installation and scalability. The units can be configured to meet specific production needs, making them suitable for both small-scale and large-scale operations. This flexibility is particularly advantageous for industries such as metal fabrication, chemical manufacturing, and medical applications, where gas demand can fluctuate significantly.

The M90ASX model boasts cutting-edge cryogenic technology that ensures high purity levels of separated gases. With a nitrogen purity of up to 99.999% and oxygen purity reaching 99.5%, users can expect top-quality outputs for their processes. This capacity is crucial for industries that require precise gas compositions, such as the aerospace sector, where even minor impurities can lead to critical failures.

Additionally, the Zephyr ASU systems are equipped with advanced monitoring and control systems. These smart technologies employ real-time data analytics to optimize performance and efficiency. Users can monitor production metrics remotely, allowing for proactive maintenance and minimizing downtime.

Energy efficiency is a standout attribute across the entire ASU range. These models utilize low power consumption technologies, which not only reduces operational costs but also lessens their environmental impact. This eco-friendly approach aligns with modern industrial goals of sustainability.

The ALA – E42ABX, ALA – M90ABX, and ALA – M90AWX models complement the M90ASX in terms of offering additional configurations and tailored solutions for specific operational requirements. Their shared technological framework ensures compatibility and ease of integration into existing systems.

Furthermore, robust safety features are integral to the design of the Zephyr ASU series. These include fail-safe mechanisms and pressure relief systems that ensure both operator safety and equipment reliability.

In conclusion, the Zephyr ASU – M90ASX, ALA – E42ABX, ALA – M90ABX, ALA – M90AWX, AED – M90ASX is redefining air separation technology with its state-of-the-art features and eco-conscious design. By offering high purity outputs, modular flexibility, advanced monitoring, and energy efficiency, these systems stand out as leaders in the air separation industry. They are poised to meet the diverse needs of various sectors while promoting sustainable industrial practices.