Wolf Appliance Company IM15 manual GAS Supply Line

Page 6

Multi-Function Cooktop Specifications

6

 

 

Gas Supply Requirements

EXPLOSION HAZARD: Use a certified gas supply line and install a gas shut-off valve. Securely tighten all gas connections. Failure to follow these instructions can result in explosion, fire or death.

IMPORTANT NOTE: This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code ANSI Z223.1—latest edition or CANI—B149.1 or 2.

The gas multi-function cooktop is equipped for use with natural or LP gas. It is design certified by the Canadian Standards Association (CSA) for natural or LP gases. The product rating plate, located on the underside of the cooktop, has information on the type of gas that should be used. Refer to the illustration below. If this information does not agree with the type of gas available, contact your authorized Wolf dealer or local gas supplier. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.

GAS SUPPLY LINE

IMPORTANT NOTE: The gas multi-function cooktop must be connected to a regulated gas supply.

Agas supply line of 3/4" (19) rigid pipe must be provided to the cooktop. For LP gas, piping or tubing size can be

1/2" (13) minimum. LP gas suppliers usually determine the size and materials used on the system. If local codes permit, a certified, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended to connect the cooktop to the gas supply line. The gas pressure regulator on the cooktop has 1/2" (13) female threads.

IMPORTANT NOTE: The supply line must be equipped with an approved external gas shut-off valve located near the cooktop in an accessible location. Do not block access to the shut-off valve. Refer to the illustration below.

The Wolf natural gas multi-function cooktop will function up to an altitude of 10,250' (3124 m) without any adjust- ment. LP gas cooktops will function up to 8,600' (2621 m) without adjustment. If the installation exceeds these eleva- tions, contact your authorized Wolf dealer for a high altitude conversion kit.

RATING PLATE

SHUT-OFF VALVE

OPEN POSITION

TO APPLIANCE

GAS SUPPLY

Before connecting the gas supply, make sure all valves are in a closed position. Do not connect the gas supply to an appliance that shows any sign of damage.

Location of rating plate.

Gas shut-off valve.

Image 6
Contents Multi-Function Cooktop Contents Important NoteImportant Instructions Multi-Function Cooktop Specifications Overall Dimensions Installation SpecificationsMULTI-FUNCTION Cooktop Side GAS Supply Line GAS Manifold Pressure Wiring Diagram Electrical GroundMultiple Cooktop Installation Multiple CooktopsMulti-Function Cooktop Installation Install the Cooktop GAS Leak Testing GAS Pressure RegulatorGAS Supply Connection Complete the Installation Verify OperationMulti-Function Cooktop Installation Cooktop Removal TroubleshootingService Information Page 800.222.7820

IM15 specifications

The Wolf Appliance Company IM15 is an innovative marvel in home appliance technology, designed specifically for those who desire the finest in kitchen equipment. Renowned for its premium quality and exceptional performance, the IM15 stands out as an ice maker that caters to both residential and commercial needs.

One of the primary features of the IM15 is its ability to produce a high volume of clear, restaurant-quality ice. With a production capacity of up to 28 pounds of ice in a 24-hour period, this appliance ensures that you will never run short of ice during gatherings or in a busy kitchen environment. The IM15 produces large, crystal-clear ice cubes that are ideal for cocktails, drinks, and culinary presentation.

The IM15 is equipped with advanced technologies that enhance its efficiency and user experience. It features a self-cleaning option that simplifies maintenance with just the touch of a button, ensuring that the ice maker stays clean and operational without the hassle of manual intervention. This function is particularly useful in maintaining hygiene and prolonging the lifespan of the appliance.

In terms of design, the IM15 exemplifies Wolf's commitment to combining functionality with aesthetics. The unit features a sleek, professional-grade stainless steel finish that complements any kitchen decor. Its compact size allows for easy integration into various cabinetry layouts, making it a versatile addition to kitchen spaces, bars, or outdoor entertaining areas.

Another characteristic of the IM15 is its user-friendly interface. The easy-to-read control panel includes features that allow users to monitor ice levels and adjust settings swiftly. This operational simplicity enables even the most novice users to produce ice effortlessly.

Furthermore, the IM15 incorporates energy-efficient technologies, ensuring that it operates with minimal environmental impact. It is designed to cool efficiently while consuming less energy, which is increasingly important for modern consumers who are more conscious of their ecological footprint.

Overall, the Wolf Appliance Company IM15 is a definitive choice for anyone seeking high performance, versatility, and style in an ice maker. Its blend of advanced features, high-quality materials, and user-friendly design makes it a standout appliance for both residential and commercial kitchens. With the IM15, you are investing in a reliable product that promises to enhance your culinary creations and entertaining experiences.