Wolf Appliance Company CT15G/S dimensions D E L O P T I O N S, N T I L a T I O N O P T I O N S

Page 3

Planning Information

Integrated Gas Cooktop

M O D E L C T 1 5 G / S

Model CT15G/S

M O D E L O P T I O N S

Classic Stainless Steel

CT15G/S

Natural gas model listed, for LP gas add (-LP) to the model number.

V E N T I L A T I O N O P T I O N S

30" (762) Cooktop hood or Pro wall or wall chimney hood or liner

30" (762) or 45" (1143) downdraft ventilation system

36" (914) Pro island hood

For additional information, refer to the Cooktop or Pro Ventilation sections of our website, wolfappliance.com.

A C C E S S O R I E S

Filler strip

Bracket supports for installation of two integrated modules with downdraft (Model DD30 only)

High altitude conversion kit

Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.

Unit dimensions may vary by ± 1/8" (3).

S P E C I F I C A T I O N S

Overall Cooktop Width

15" (381)

 

 

 

Overall Cooktop Height

4"

(102)

 

 

 

Overall Cooktop Depth

21"

(533)

 

 

 

Burner Rating

One 12,000 Btu/hr (3.5 kW) burner with 800 Btu/hr (.2 kW) delivered at simmer

One 9,200 Btu/hr (2.7 kW) burner with 300 Btu/hr (.1 kW) delivered at simmer

Minimum Cabinet Depth

22 3/4" (578)

Minimum Height Clearance

4" (102)

 

 

Cooktop Cut-Out Width

14" (356)

 

 

Cooktop Cut-Out Depth

19 1/4" (489)

Electrical Supply Requirements

120 V AC, 60 Hz

 

 

15 amp circuit

 

 

 

Power Cord

 

6' (1.8 m) power cord

 

 

with grounded plug

 

 

 

Gas Rating

 

21,200 Btu/hr (6.2 kW)

 

 

 

Shipping Weight

 

30 lbs (14 kg)

 

 

Special Note

Cooktop can be installed in combination

 

with other cooktops or modules

 

 

 

Specifications are subject to change without notice.

Dimensions in parentheses are in

 

millimeters unless otherwise specified.