Maintenance | |
|
|
Troubleshooting
Refer to the table below for troubleshooting information.
Problem | Cause | Possible Solution |
Shelves Not Heating and | Unit not plugged into power | Ensure unit power cord is |
Lights Not On | receptacle. | connected to appropriate power |
|
| receptacle. |
| No Power to the unit. | Check circuit breaker or fuses at |
|
| building power panel. If problem |
|
| persists, contact an authorized |
|
| BKI service agent for corrective |
|
| action. |
| Power circuit breaker is OFF | Place the Power circuit breaker |
| and Lights circuit breaker is | ON and the Lights circuit breaker |
| OFF. | ON. |
Power Circuit Breaker has | Overload, short circuit or ground | Place circuit breaker actuator in |
Tripped | fault condition exists. | the ON position. If circuit breaker |
|
| trips again, contact an authorized |
|
| BKI service agent for corrective |
|
| action. |
No Heat to Single Shelf | Power circuit breaker is OFF. | Place the Power circuit breaker |
|
| ON. |
| Shelf Temperature control is | Adjust the shelf temperature |
| turned fully counterclockwise. | control. Refer to the section |
|
| entitled Temperature Adjustment |
|
| on page 4. |
| Defective Shelf. | Contact an authorized BKI service |
|
| agent for corrective action. |
| Loose Wire or bad Connection. | Contact an authorized BKI service |
|
| agent for corrective action. |
| Shelf Temperature control is | Contact an authorized BKI service |
| defective. | agent for corrective action. |
Individual Light is not On | Failed fluorescent lamp. | Change fluorescent lamp. |
| Possible Ballast failure. | Contact an authorized BKI service |
|
| agent for corrective action. |
Holding Temperature Not | Unit has not been preheated. | Refer to the preheating section on |
Adequate |
| page 4. If problem persists, |
|
| contact an authorized BKI service |
|
| agent for corrective action. |
| Product is below 160° F when | Check product temperature |
| loaded. | before loading the unit. |
| Loose Wire or bad Connection. | Contact an authorized BKI service |
|
| agent for corrective action. |
|
|
|
| Shelf temperature control not | Adjust the shelf temperature |
| set properly. | control. Refer to the section |
|
| entitled Temperature Adjustment |
|
| on page 4. |
Switch Plate Pilot Light is | Overtemperature condition | Turn unit OFF then contact an |
On | exists. Possible fan failure. | authorized BKI service agent for |
|
| corrective action. |
10