81/4”
(210mm)
42 3/4”
(1086mm)
43"
(1092mm)
8" (203mm)
|
|
| 43" |
|
|
|
|
| (1092mm) |
|
|
3/4" NPT |
|
|
|
| |
GAS INLET |
|
|
|
| |
|
| 8 1/4" |
|
|
|
|
| (210mm) | 8" (203mm) |
|
|
|
|
|
| 24" |
|
24" |
| 54" | 3/4" NPT | (610mm) |
|
|
|
| |||
(610mm) | (1372mm) |
| 62 1/4” | ||
GAS INLETS |
| ||||
|
| 52 3/4” |
| ||
|
|
|
| (1581mm) | |
52 1/4” | (1340mm) |
|
| ||
|
|
| |||
(1327mm) |
|
|
|
| |
|
|
| 8" (203mm) | 24" | 64" |
|
|
|
| (610mm) | (1626mm) |
30" |
|
|
| 38 1/4” | |
(762mm) |
|
|
| (972mm) | |
|
| 28 3/4” |
|
|
|
|
| (730mm) |
|
|
|
|
|
|
| 16" |
|
|
|
|
| (406mm) |
|
8 1/4" (210mm)
663/4"
(1695mm)
423/4"
(1086mm)
18 3/4" (476mm)
SINGLE UNIT RH SIDE VIEW
43"
(1092mm)
8" (203mm)
8" (203mm)
3/4" NPT GAS INLETS
8" (203mm)
STACKED UNIT RH SIDE VIEW
STACKED UNIT
RH SIDE VIEW
3/4" NPT GAS INLET
24" |
|
|
|
|
|
(610mm) |
|
|
|
|
|
|
| 1 1/8" (29mm) |
| WIDTH |
|
|
|
| 4 3/4" (121mm) |
| |
|
|
| 3/4" NPT |
| |
|
|
| DECK |
| |
|
|
| GAS INLET |
| |
|
|
|
|
| |
|
| 78" |
|
|
|
24" |
| (1981mm) |
|
|
|
|
|
|
|
| |
(610mm) |
|
|
|
|
|
| 52 1/4" | 76 1/4" | 8 1/8" | Flue Vent 6" (152mm) dia | 43" |
| (1327mm) | (1937mm) | (206mm) | (1092mm) | |
|
| ||||
|
|
|
|
| 34 5/8" |
24" |
| 54" | 3/4" NPT |
| (879mm) |
|
|
| |||
(610mm) | (1372mm) | GAS INLET |
|
| |
38 1/4" |
|
|
|
| |
(972mm) |
|
|
|
| |
|
|
| 11 1/4" |
|
|
|
|
| (286mm) | FULL WIDTH DOOR OPENING | 3 1/2" |
|
|
|
| ||
6" |
|
|
|
| (89mm) |
(152mm) |
|
|
| TOP VIEW |
|
ALL DIMENSIONS NOMINAL
| SHIPPING INFORMATION |
|
|
|
|
|
|
|
|
| |||
|
| Shipping Weight |
| Carton Dimensions |
| Crate Size |
| ||||||
| Model | Lbs. | Kilos | Width | Depth | Height | Cubic | Cubic | |||||
| Inches | mm | Inches | mm | Inches | mm | Feet | Meter |
| ||||
|
|
|
| ||||||||||
| 251 | 820 | 372 | 53 | 1346 | 40 | 1016 | 37 | 940 | 44.4 | 1.4 |
|
|
351 | 958 | 434 | 52 | 1321 | 36 | 914 | 72 | 1829 | 76.2 | 2.7 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
451 | 1093 | 496 | 52 | 1321 | 36 | 914 | 72 | 1829 | 76.2 | 2.7 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6"
(152mm)
12" (305mm)
For Direct Venting
Not available on CE units
MUST BE SPECIFIED AT TIME OF ORDER
6"
(152mm)
12"
(305mm)
For Installation Under
Ventilation Hood
STANDARD
Shipping Class # 70 |
|
|
|
|
|
|
|
|
|
|
| ||
Each oven ships separately |
|
|
|
|
|
|
|
|
|
|
| ||
Hearth decks & legs ship in separate cartons |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SPECIFICATIONS |
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Deck Size |
| # |
|
| Overall Dimensions |
|
|
| ||
| Model |
|
| Height | Decks | Width | Depth | *Height | |||||
| Inches | mm | Inches | mm | Inches | mm | Inches | mm | Inches | mm |
| ||
| 251 | 36x34 1/2 | 914x876 | 8 | 203 | 1 | 48 | 1219 | 43 | 1092 | 54 | 1372 |
|
| 252 | 36x34 1/2 | 914x876 | 8 | 203 | 2 | 48 | 1219 | 43 | 1092 | 64 | 1626 |
|
| 253 | 36x34 1/2 | 914x876 | 8 | 203 | 3 | 48 | 1219 | 43 | 1092 | 78 | 1981 |
|
| 351 | 45x34 1/2 | 1143x876 | 8 | 203 | 1 | 57 | 1448 | 43 | 1092 | 54 | 1372 |
|
| 352 | 45x34 1/2 | 1143x876 | 8 | 203 | 2 | 57 | 1448 | 43 | 1092 | 64 | 1626 |
|
| 353 | 45x34 1/2 | 1143x876 | 8 | 203 | 3 | 57 | 1448 | 43 | 1092 | 78 | 1981 |
|
| 451 | 54x34 1/2 | 1372x876 | 8 | 203 | 1 | 66 | 1676 | 43 | 1092 | 54 | 1372 |
|
| 452 | 54x34 1/2 | 1372x876 | 8 | 203 | 2 | 66 | 1676 | 43 | 1092 | 64 | 1626 |
|
453 | 54x34 1/2 | 1372x876 | 8 | 203 | 3 | 66 | 1676 | 43 | 1092 | 78 | 1981 |
| |
* Height includes 30" (762 mm) standard legs on models 151,3151,4151 | * Height includes 6" (152 mm) standard legs on models 153,3153,4153 | ||||||||||||
* Height includes 16" (406 mm) standard legs on models 152,3152 ,4152 | CE approved units may only be stacked two high |
|
|
|
|
|
| GAS SUPPLY |
|
|
|
|
|
|
| |||
|
|
|
| Model | BTUH | KW | CONNECTION |
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||||
|
|
| 251 | 60,000 | 18 | 3/4" |
|
|
| ||||
|
| 351 | 70,000 | 21 | 3/4" |
|
|
| |||||
|
|
|
|
|
|
|
|
| |||||
|
| 451 | 80,000 | 24 | 3/4" |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| Each oven requires separate gas connection |
|
|
|
|
| ||||
|
|
|
| CE certification not available in LP gas |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MINIMUM CLEARANCES |
|
|
|
|
|
|
| |||||
|
|
|
|
| Combustible Construction** | ||||||||
|
|
|
|
| Inches |
| mm |
| Inches |
| mm | ||
| Left Side | 0 |
| 0 |
| 1 |
| 25 |
| ||||
| Right Side | 0 |
| 0 |
| 3 |
| 76 |
| ||||
| Rear | 2 |
| 51 |
| 3 |
| 76 |
|
*In European Community Countries and North America. In
**In European Community Countries only in COMBUSTIBLE locations. NOT for North America.
| BAKERS PRIDE OVEN COMPANY, INC. | |
BAKERS | 30 Pine Street, New Rochelle, NY 10801 | |
| ||
PRIDE | ||
www.bakerspride.com | ||
| ||
|
Continuous product improvement is a policy of Bakers Pride Oven Company. Therefore, specifications and design are subject to change without notification
TSW: 07/05