4. See Fig. 7 for wiring dehumidistat to ventilator.

 

 

120V, 60 Hz

 

WHITE

SUPPLY

TO FAN

 

GROUND

MOTOR

 

 

 

BLACK

 

THERMOSTAT &

 

 

JUNCTION BOX

 

 

ASSEMBLY

 

 

 

DEHUMIDISTAT

Figure 7 — Wiring Diagram for Dehumidistat

5. Replace cover to thermostat/junction box.

OPERATION

Set automatic thermostat to meet your requirements. The ther- mostat has an adjustable range from 60º to 120º and operates on a 15º differential. For example, factory setting is 100º. At this set- ting, as soon as temperature reaches 115º, thermostat will close and start ventilator. When temperature has been reduced to 100º, thermostat will open and ventilator will stop. Dial pointer may be set at temperature that is best for local conditions.

NOTE: Remember the 15º differential. If dial point is set on 120º, ventilator will start at 135º and operate until temperature has been reduced to 120º, a difference of 15º. (See Figure 8.)

60ºF

F

 

A

 

N

Figure 8 — Thermostat

90

 

O

F

120 F

MAINTENANCE

WARNING: MOTORS ARE THERMALLY PROTECTED AND AUTOMATICALLY TEMPERATURE CON- TROLLED AND MAY START WITHOUT WARNING. THEREFORE, MAKE CERTAIN THAT POWER SOURCE IS DISCONNECTED BEFORE ANY ATTEMPT TO SER- VICE OR DISASSEMBLE ANY COMPONENTS! IF POWER DISCONNECT IS OUT-OF-SIGHT, LOCK IT IN THE OPEN POSITION AND TAG TO PREVENT APPLI- CATION OF POWER.

Lubricate motor every 6 months using SAE 20 non-detergent oil. Insert 2-3 drops of oil in the oiling hole on the back plate of the motor.

TROUBLESHOOTING CHART

WARNING: ITEMS MARKED WITH AN ASTERISK (*) SHOULD BE PERFORMED ONLY BY EXPERIENCED AND QUALIFIED PERSONNEL.

SYMPTOM

 

POSSIBLE CAUSE

CORRECTIVE ACTION

Excessive

1.

Propeller blade contacting

1.

Realign or replace.

noise.

 

housing.

 

 

 

2.

Foreign material inside

2.

Clean.

 

 

housing.

 

 

 

3.

Motor loose.

3.

Secure properly.

 

4.

Motor needs oiling.

4.

See Maintenance section.

 

5.

Dirt accumulation on pro-

5.

Clean.

 

 

peller, causing imbalance.

 

 

 

 

 

 

 

Insufficient

1.

Not enough eave vents to

1.

See installation section.

air flow.

 

provide make-up air.

 

 

 

2.

Clogged screen.

2.

Clean or replace.

 

 

 

 

 

Unit fails to

1.

Blown fuse or open cir-

*1.

Replace fuse or reset cir-

operate.

 

cuit breaker.

 

cuit breaker.

 

2.

Defective motor.

*2.

Replace.

 

3.

Improper setting of ther-

*3.

See Operation section.

 

 

mostat. (REMEMBER THE

 

 

 

 

15º DIFFERENTIAL)

 

 

 

4.

Defective thermostat.

*4.

Replace

 

 

 

 

 

Image 3
Contents Important Safety Instructions Read and Save These InstructionsGable Mounted Ventilator Installation WiringMinimum Attic Intake AIR Required Operation MaintenanceParts List HOW to Order Repair PartsREF. no Description QTY

GV 16 specifications

The Marley Engineered Products GV 16 is a highly efficient and reliable solution designed to meet the evolving demands of industrial and commercial cooling applications. Known for its robust construction and advanced technology, the GV 16 stands out in the realm of cooling equipment.

One of the main features of the GV 16 is its compact design, which allows for easy integration into various systems. Its space-saving capabilities make it suitable for installations where footprint is critical. Despite its size, the GV 16 doesn’t compromise on performance; it is engineered to deliver high airflow and effective cooling in even the most challenging environments.

The GV 16 incorporates advanced airflow technology, featuring optimized fan blade geometry that enhances air movement and reduces energy consumption. This design ensures that the unit operates quietly while maintaining effective performance levels. The integration of high-efficiency motors further contributes to its energy-saving capabilities, making it an environmentally friendly choice.

Another important characteristic of the GV 16 is its durability. Constructed from high-quality materials, it is designed to withstand harsh operating conditions, ensuring a long service life. This rugged construction minimizes maintenance needs and reduces operational costs over time, making the GV 16 a cost-effective solution for users.

The GV 16 is equipped with an easy-to-use control system that allows for precise temperature regulation and monitoring. This feature ensures that users can maintain optimal performance and adjust settings as needed, contributing to overall system efficiency.

Furthermore, the GV 16 is designed with versatility in mind. Its ability to operate in both horizontal and vertical configurations makes it adaptable to various applications. This flexibility, combined with its reliable performance, makes it an ideal choice for cooling in a range of settings, from manufacturing facilities to data centers.

Overall, the Marley Engineered Products GV 16 is a powerful, efficient, and durable solution that excels in delivering reliable cooling performance. With its advanced features and technologies, it meets the needs of modern industrial and commercial applications, providing users with peace of mind and efficiency. Whether for new installations or system upgrades, the GV 16 continues to set a standard in the world of cooling technology.