INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
QuieTTest® Twin Blower Ventilator
MODEL: QT150 (For Ceiling Installation)
•Suitable for use with solid state speed controls.
•WARNING: To reduce the risk of shock, disconnect power before servicing.
•Not for use in kitchens.
•Uses standard 31⁄4" x 10" ducting.
•Plastic grille snaps in with torsion springs.
•Designed for ceiling installation.
•The ventilator consists of the housing, mounting brackets, junction box, power unit/blower assembly, damper section and grille assembly.
•Fan must not be installed in a ceiling thermally insulated to a value greater than
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including
B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back draft. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or shower.
FOR BEST RESULTS
When installing the ventilator in a new construction site, install the housing during the
To install the ventilator in an existing building, an accessible area (attic or crawl space) is required from above the planned location.
POWER
POWER CONNECTOR UNIT
SLOTS
WING NUT,
HANGER ROD
HANGER
ROD
FIGURE 1
ROOF CAP
VERTICAL
DISCHARGE
31⁄4" x 10"
DUCT
WALL CAP
KNOCKOUTS
FAN
HOUSING
HORIZONTAL
DISCHARGE
FIGURE 2
VERTICAL DISCHARGE
31⁄4" x 10" DAMPER SECTION
31⁄4" x 10"
DAMPER SECTION
HORIZONTAL
DISCHARGE
FIGURE 3