NuTone NP60000 installation instructions To reduce the risk of fire and to properly exhaust

Page 2

! WARNING

! WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.Do not use this unit with any additional solid-state speed control device.

8. To reduce the risk of fire, use only steel ductwork.

9.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner.

BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN—You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels—This could cause a violent steam explosion.

4.Use an extinguisher ONLY if:

A.You own a Class ABC extinguisher and you know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department has been called.

D.You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced.

4.For best capture of cooking impurities, the bottom of the hood should be at a minimum of 24” and at a maximum of 30” above the cooking surface.

5.Two installers are recommended because of the large size and weight of this hood.

a)

Never leave surface units unattended at high settings.

6.

To reduce the risk of fire and to properly exhaust

 

Boilovers cause smoking and greasy spillovers

 

air, be sure to duct air outside—Do not exhaust air

 

that may ignite. Heat oils slowly on low or medium

 

into spaces within walls or ceiling or into attics,

 

settings.

 

crawl space or garage.

b)

Always turn hood ON when cooking at high heat or

7.

This product is equipped with a thermostat which

 

when flambeing food (Crêpes Suzette, Cherries

 

may start blower automatically. To reduce the risk

 

Jubilee, Peppercorn Beef Flambé).

 

of injury and to prevent power from being switched

c)

Clean ventilating fans frequently. Grease should

 

on accidentally, switch power off at service panel

 

and lock or tag service panel.

 

not be allowed to accumulate on fan or filter.

 

 

8.

Because of the high exhausting capacity of this

 

 

d) Use proper pan size. Always use cookware appropriate

 

hood, you should make sure enough air is entering

 

for the size of the surface element.

 

the house to replace exhausted air by opening a

 

 

 

window close to or in the kitchen.

 

 

9.

To reduce the risk of fire and electric shock, the

 

 

 

NuTone Premier NP60000 Series hood must be

 

 

 

installed with NuTone interior blower models

 

 

 

RM325H or RM326H; NuTone exterior blower models

 

 

 

331H, 332H, 335 or 336; NuTone in-line blowers

 

 

 

models HLB3, HLB6, HLB9, HLB11. Other blowers

 

 

 

cannot be substituted. (Blowers sold separately.)

 

 

10.

Use with approved cord-connection kit only.

 

 

11.

Please read specification label on product for

 

- 2 -

further information and requirements.

 

 

Image 2
Contents NP60000 Series To reduce the risk of fire and to properly exhaust Warranty NP60000 Series Range Hood System Interior Blowers RMP Series Select Blower Option and Install Ductwork Model RM325H Single Blower Typical DuctworkMeasure Installation Prepare the InstallationInstall the Hood Install Backsplash OptionalInstall Wood Mounting Strip Install Transition to ROUGH-IN Plate Interior Blower onlyInstall the Optional Soffit Chimney Install the ROUGH-IN Plate to the Hood ALL BlowersConnect the Wiring ALL Blowers Install the Blower Interior or Exterior BlowerBaffle Filters Install Light Bulbs and Warming LampsInstall Filters USE and Care Operation Service Parts QTY Hood Width Number Description

NP60000 specifications

The NuTone NP60000 is a versatile and advanced ventilation fan designed to improve indoor air quality and enhance comfort in both residential and commercial spaces. One of the key features of the NP60000 is its quiet operation. Equipped with a powerful motor that operates at a low decibel level, this fan ensures a peaceful environment, making it ideal for use in bathrooms, kitchens, and living areas where noise can be a concern.

Another significant aspect of the NuTone NP60000 is its efficient air circulation capabilities. With an impressive airflow rating, the fan effectively moves a substantial volume of air, aiding in the removal of moisture, odors, and pollutants. This not only helps in maintaining a healthy atmosphere but also prevents mold and mildew from forming, particularly in high-humidity areas.

The NP60000 integrates seamlessly with modern technology. It features smart functionality that allows users to control the fan remotely, either through a smartphone app or a compatible smart home system. This means you can operate the fan from anywhere in your home, providing a level of convenience and control that was previously unattainable in traditional ventilation systems.

Energy efficiency is another hallmark of the NuTone NP60000. Designed with energy-saving technologies, it consumes less power compared to conventional fans without compromising performance. This characteristic not only translates to lower energy bills but also aligns with environmentally friendly practices, making it a smart choice for eco-conscious consumers.

The design of the NP60000 is both sleek and functional. It comes with a stylish grille that can complement various interior design styles, ensuring that it blends in with your decor while providing necessary ventilation. Additionally, installation is straightforward, making it accessible for homeowners looking to upgrade their ventilation systems easily.

In summary, the NuTone NP60000 stands out for its quiet operation, impressive airflow, smart technology integration, energy efficiency, and stylish design. Whether you’re renovating your home or looking to improve air quality in a commercial space, the NP60000 is a reliable option that brings together performance and convenience, making it a leading choice in the ventilation fan market.