SHUTTER INSTALLATION

STEP 10 — Unpack Model A3024 shutter and read instruc- tions included. Note that the first part of the shutter instruc- tions refer to cutting the shutter hole, which you have already done, and so they may be disregarded. Follow the remaining instructions to adjust springs so that shutters open and close freely. (See Fig. 8.)

STEP 11 — Mount shutter to joists directly below fan opening with wood screws provided. Note sheet rock must be cover- ing center joist before shutter is installed. Again, make sure both sides of shutter open and close freely. (See Fig. 9.)

STEP 12 — Return to attic and attach side panels to fan as shown using remaining short screws and washers. (See Fig. 10.) Bottom of panels should rest upon ceiling. Bend flaps on ends of panels back when inserting panels between joists. These flaps will then spring back to seal off any space between panel and joist.

STEP 13 — Fan installation is now complete. With control in “OFF” position turn on 120V power supply to fan. Test run fan through all speeds.

WALL INSTALLATION MODEL 3130 SHUTTER

THIS INSTALLATION IS TO BE USED ONLY IN AN ATTIC GABLE OR WALL WHICH FACES AN UNOCCUPIED AREA, AN AREA NOT READILY ACCESSIBLE TO PEO- PLE OR ANIMALS! DO NOT USE THIS INSTALLATION IN AN ATTIC WITH ANY TYPE OF LOOSE INSULATION.

STEP 1 — Construct wood frame as shown in Figs. 11 & 12. Use 2 x 8 framing lumber and 2 x 2 furring strips.

STEP 2 — Drill (4) holes 14” in diameter in fan housing as shown in Fig. 13.

STEP 3 — Position fan in frame and secure with (4) wood or lag screws (#12 x 112” preferred) through holes drilled in Step 2. Note 334” dimension from edge of frame. (Fig. 14)

STEP 4 — Secure Model 3130 shutter with (8) wood or lag screws (#12 x 1” preferred) through holes in shutter frame. Shutter should be positioned so that louvers swing outward and upward. See Fig. 15. Check shutter to make sure it opens and closes freely. Also check to make sure there is clearance between shutter and fan blade.

STEP 5 — To mount this attic fan in gable or wall, a box must be framed into wall construction as shown in Fig. 16. Make opening in outside wall 37” x 37”.

STEP 6 — Insert frame containing fan and shutter assembly into opening with outside surface of shutter frame flush with outside surface of wall. See Fig. 16.

FIG. 8

SPRING ATTACHED

CONNECTOR

SPRING SHOWN

UNATTACHED

FIG. 9

FIG. 10

FIG. 11

SPRING HOLDER

LOCKING

SCREW

— 5 —

Image 5
Contents Read and Save These Instructions Important Safety Instructions Locating & Mounting FAN Ceiling InstallationSupply Available AT Control WiringSupply Available AT FAN Wall Installation Model 3130 Shutter Shutter InstallationFAN Unrestricted Wood Louver Metal Louver Size Opening Reqd Attic AIR Intake and DischargeMinimum Attic Discharge Areas Required Description ModelDescription QTY Used onHOW to Order Repair Parts AccessoriesLimited Warranty Operating Hints and Suggestions

A24DD specifications

Marley Engineered Products has long been recognized for its innovative solutions in the field of HVAC and fluid handling technologies. One of its outstanding offerings is the A24DD unit, a high-performance fan and heater combination designed to maximize efficiency and comfort in various applications.

The A24DD is strategically engineered with a focus on versatility. It is suitable for use in industrial, commercial, and residential settings, making it a popular choice among contractors and facility managers. Its compact design allows for easy installation in tight spaces, which is ideal for businesses that need to optimize their operational areas without compromising on heating solutions.

A key feature of the A24DD is its advanced airflow technology. The unit utilizes a direct drive motor, which not only enhances energy efficiency but also reduces noise levels, providing a quieter environment. This characteristic is particularly beneficial in settings where noise pollution can affect comfort or productivity, such as offices and schools.

The A24DD is equipped with a robust heating element that ensures rapid heat distribution, contributing to a warm and comfortable atmosphere in no time. The built-in safety features, including over-temperature protection and adjustable thermostat controls, enhance user safety and comfort. This system provides users the flexibility to adjust the temperature settings to meet their specific needs, ensuring efficient energy use.

In terms of durability, the A24DD stands out with its high-quality materials and construction. It is designed to withstand harsh conditions, making it an excellent option for various industrial applications. The corrosion-resistant housing ensures longevity, while the easy maintenance features reduce the total cost of ownership.

Another highlight of the A24DD is the integration of smart technologies. It can be linked with existing building management systems, allowing for streamlined operation and energy monitoring. This capability not only supports energy efficiency goals but also aids in maintaining the operational reliability of heating systems.

In summary, the Marley Engineered Products A24DD unit combines flexibility, efficiency, and advanced technology, making it a top choice for those seeking reliable heating solutions across a broad spectrum of environments. With its user-friendly features and commitment to safety and efficiency, the A24DD is redefining comfort and performance in heating systems.