Installation
The oven must be installed according to the | This oven must be installed by qualified | |||
instructions supplied. |
| personnel to the relevant British Standards. | ||
Technical Data |
| Heating elements rating |
| |
Dimensions of recess |
| Convection element | 2,000 W | |
| Grill | 1,650 W | ||
Height | 580 mm | |||
Oven Light | 25 W | |||
Width | 560 mm | |||
Depth | 550 mm | Cooling Fan | 25 W | |
|
| Convection Fan | 25 W | |
Dimensions of the oven cavity |
| Total Rating | 2,075 W | |
Height | 335 mm | |||
Supply voltage (50 Hz) | 230 V | |||
Width | 405 mm | |||
|
| |||
Depth | 400 mm |
|
| |
Oven capacity | 56 litres |
|
|
Electrical Connection
The oven is designed to be connected to 230 V (50 Hz) electricity supply.
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Live terminal | |||||||
Letter N | - | Neutral terminal | |||||||
|
|
|
|
|
|
| or E | - | Earth terminal |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must comply to the specifications given below.
For Uk use only
Connection | Min. size | Cable / flex | Fuse |
via | Cable/flex | type |
|
• 13 A socket | 2.5 mm2 | 3 core | 13 A |
outlet |
| butyl | min. |
• 13 A |
| insulated |
|
spur box |
|
|
|
|
|
|
|
• Cooker | 2.5 mm2 | PVC/PVC | 15 A min. |
Control |
| twin and | 20 A max. |
Circuit |
| earth |
|
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
Themanufacturerdisclaimsanyresponsibilityshould these safety measures not be carried out.
For Europe use only
Min. size Cable/flex | Cable / flex type | Fuse |
|
|
|
1.5 mm2 | H07 | 13 A |
| H05 |
|
| H05 |
|
| H05 |
|
|
|
|
17