Something Not Working
If your appliance is not operating correctly, carry out the following checks before contacting your local Service Force Centre.
Important: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or ins- tallation a charge will be made, even if the appliance is under guarantee.
Symptom | Cause | Solution |
Interior Light (refrigerator) | • Appliance is not plugged in | • Plug in the appliance |
|
|
|
does not work | • The appliance is not switched on | • Switch on the appliance |
|
|
|
| • There is no power to the appliance | • Check the main fuse box in the |
|
| house |
|
|
|
| • The bulb is not fitted correctly or | • Refit the bulb or replace with a |
| has fused. | new bulb |
The appliance does not cool | • The doors have not been closed | • Close the doors |
down sufficiently | properly |
|
|
|
|
| • A door has been opened frequently | • Avoid frequent opening of the |
|
| doors |
|
|
|
| • The temperature control knob is | • Reset as required |
| not set correctly |
|
|
|
|
| • Food has been introduced into the | • The appliance will cool down in |
| appliance | due course. |
|
|
|
Food is freezing in the fridge | • The temperature control knob | • Reset as required |
| is incorrectly set |
|
|
|
|
| • Food is too close to ventilation | • Reposition food, leaving a gap. |
| holes at the back |
|
|
|
|
The motor works | • Temperature control knob is | • Change the setting |
continuously. | incorrectly set |
|
| • The doors are not properly closed | • Close the doors |
|
|
|
| • Doors have been opened frequently | • Avoid frequent opening of the doors |
|
|
|
| • Food has recently been introduced | • The appliance will cool down in |
| into the appliance | due course. |
|
|
|
| • The condenser is dirty | • Clean (read the Maintenance & |
|
| Cleaning section). |
|
|
|
Water/condensation in the | • Wet vegetables have been put | • This may occur from time to time |
vegetable drawer | into the box |
|
Condensation on the | • High humidity level in the room. | • It does not affect the performance |
outside of the cabinet |
| of the appliance. Increase the |
|
| room ventilation. |
Doors do not close | • The appliance is not level | • Level the appliance correctly |
|
|
|
| • The doors are incorrectly aligned | • |
|
|
|
| • Food is preventing the doors | • |
| shutting |
|
|
|
|
Noises | • The appliance may not be level | • Level the appliance |
|
|
|
| • Something may be vibrating inside | • Check the contents and shelves |
|
| are properly positioned. |
|
|
|
All product lights start | • Your product has a major fault | • Contact your local Service |
flashing and the alarm sounds |
| Force Centre |
|
|
|
8