Zanussi ZE 76/3 W manual Something not Working, Symptom Solution, Low ambient operation

Page 12

SOMETHING NOT WORKING

Important: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or installation a charge will be made, even if the appliance is under guarantee.

Before contacting your local Service Force Centre, check the following points:

Symptom

Solution

 

 

No power to the appliance

Check there is power at the socket.

 

 

 

Check there is not a power cut by checking the

 

household lights.

 

 

 

Check the fuse has not blown.

 

 

The light does not come on

Ensure that the bulb is correctly fitted.

 

 

 

Replace the bulb if it has blown.

 

 

 

Check the door light switch is not jammed.

 

 

The temperature in the fridge or freezer section is

Check the thermostat control knob is turned to the

too high

correct setting relative to ambient conditions.

 

 

 

Check the ambient temperature is within the

 

applianceÕs operating limits of 10¡C to 32¡C.

 

Relocate the appliance if necessary.

 

 

The freezer door will not open

Has door just been opened? If so leave for a few

 

minutes to allow the air pressure to equalise.

 

 

The compressor runs continously

Adjust the thermostat control knob to give correct

 

temperature control. See ÒSetting the temperatureÓ.

 

 

 

Check that the doors are closed.

 

 

 

Large quantities of food have recently been placed in

 

the cabinet and/or door is frequently opened.

 

 

 

Check that air ventilation is not obstructed.

 

 

Excessive frost and ice has built up

Ensure the doors are not left open.

 

 

 

Check that nothing is preventing the doors from

 

closing.

 

 

 

Is the door gasket intact and clean.

 

 

 

Has advised periodic defrosting been carried out.

 

 

Noise

Refer to normal operating sounds.

 

 

Water under the salad crispers

Check the drain hole is not blocked. (see

 

Maintenance and Cleaning).

 

 

Low ambient operation

During prolonged periods of low ambient temperatures,ie;10¡C and lower, the compressor on single compressor fridge freezers can remain inoperative during this time .

This is due to the air temperature within the refrigerator compartment being maintained at 6¡C or under thus not calling the thermostat to energise the compressor .

12

Image 12
Contents Refrigerator Freezer Important Safety Information InstallationContents Description of the Appliance Operation Frozen food storage ThawingMaking ice cubes Cold accumulatorsUse and features of the Crispõn Fresh filter Movable shelvesPositioning the door shelves Cool Check Guide Positioning of the Cool CheckIf the Cool Check shows TOO Warm Hints and TipsEnergy Saving Advice Event of a Power FailureHints and Tips Normal Operating SoundsMaintenance and Cleaning Defrosting RefrigeratorFreezer Symptom Solution Something not WorkingLow ambient operation Service and Spare Parts Customer Care Department7 0 5 9 2 9 9 2 Guarantee Conditions Standard guarantee conditionsEuropean Guarantee ExclusionsTechnical Specifications Star RatingInstallation PositioningRear spacers Electrical connections Green and Yellow Earth Blue- Neutral Brown- LiveDoor reversal directions Page Electrolux Household Appliances Limited