![](/images/new-backgrounds/1089525/8952513x1.webp)
ATTACH THE SUPPORT
1. Put a thick, protective |
| ||
| |||
covering over cooktop, |
| ||
| |||
to protect from damage |
| ||
or dirt. |
| ||
2. Determine and clearly |
| ||
mark with a pencil on the |
| ||
ceiling. | wheretherangehood |
| |
will be installed. |
| ||
3. Atemplate(LinFIGURE |
| ||
6) for mounting the support |
| ||
is supplied in the carton |
| ||
with the support. Use this |
| ||
template to mark holes for | FIGURE 6 | ||
support on the ceiling. | |||
| |||
|
4. Determine and make necessary cuts for the ductwork. The duct opening is shown on the mounting template (L in FIGURE 6). Install ductwork before mounting the support.
5. IfusingtheHighCeiling Chimney Kit, remove the CHIMNEY COVER from the CHIMNEY EXTENSION (A in FIGURE 7). Position the
CHIMNEY EXTENSION over the CHIMNEY SUPPORT(BinFIGURE
7) so that the outside edges and the electrical holes line up. Attach the CHIMNEYEXTENSIONto theCHIMNEYSUPPORT
using the 4 bolts (C inFIGURE 7 FIGURE 7). Tighten bolts
securely.
6.Determine the proper location for the Power Supply Cable as indicated on the template. Use a 1 1/4" Drill Bit to make this hole. Run the Power Supply Cable. Use caulking to seal around the hole. DO NOTturnonthepoweruntilinstallationiscomplete!Aknockoutis provided at the top of the CHIMNEY SUPPORT (D in FIGURE 8).
7.For ducted installations, place the round DAMPER (N in FIGURE 1) into the exhaust opening of the rangehood and press down.
FIGURE 8
8.Attach the CHIMNEY SUPPORT (D in FIGURE 8) to the ceiling. Makesure thatthesupportisfirmlyattached tothe ceiling. Determine the desired length of the support structure and adjust the length of the support by removing the four screws (indicated in FIGURE 8) with a flat head screwdriver. Once the length of the support is determined, install and tighten the four screws.
FOR DUCTLESS INSTALLATIONS
Ductless installations require a Ductless Conversion Kit whose components are pictured in FIGURE 9. Do not use the DAMPER (N in FIGURE 1) for ductless installations. The LOWER CHIMNEY COVER (B in FIGURE 1) should be discarded and replaced by the new one with holes from the DuctlessConversionKit (D in FIGURE 9).
As indicated in | FIGURE |
|
9, place the DUCTLESS |
| |
DIVERTER (A) | over the |
|
exhaust opening of the EASY |
| |
CUBE (E). FittheDUCTLESS |
| |
DIVERTER EXTENSIONS |
| |
HORIZONTAL (B) into the | FIGURE 9 | |
DIVERTER (A). |
| |
|
|
MAKE THE ELECTRICAL CONNECTION
Remove the cover from the field wiring compartment. DO NOT turn on the power until installation is complete! Connect the Power Supply Cable to the rangehood. Connect the Green (Green and Yellow) ground wire under the Green grounding screw. Attach the White lead of the power supply to the White lead of the rangehood with a
INSTALLING THE RANGEHOOD
1. The UPPER CHIMNEY |
|
COVER (C in FIGURE 10) |
|
attaches using two screws |
|
provided (G in FIGURE 10). |
|
If using the High Ceiling |
|
Chimney Kit, use the |
|
UPPER CHIMNEY COVER |
|
supplied with the kit. Slide |
|
up and attach the UPPER |
|
CHIMNEY COVER. |
|
2. Attach theductworkto the |
|
DAMPER (N in FIGURE 1). |
|
Make sure to seal all joints |
|
with duct tape to prevent |
|
leaks. |
|
3. The LOWER CHIMNEY |
|
COVER (B in FIGURE |
|
10) attaches using two |
|
screws provided (G in |
|
FIGURE 10). Install the |
|
LOWERCHIMNEYCOVER | FIGURE 10 |
For ductless installations, line up the DUCTLESS DIVERTER EXTENSIONS HORIZONTAL (B in FIGURE 9) with the holes in the LOWER CHIMNEY COVER (D in FIGURE 9) and snap in the VENT GRIDS (C in FIGURE 9).
Version 1/06 - Page 7