Hunter Fan 83001 manual Preventative Maintenance

Page 2

W a r n i n g

TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty.

2.Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhaust- ing of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards,

such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible.

7.Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit.

8.Install fan at least 5 feet (1.52 m) above the floor.

9.Never place a switch where it can be reached from a tub or shower.

10.This unit must be grounded.

11.For supply connection, use wires suitable for at least 90º C (194º F).

C A U T I O N

1.For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials.

2.To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further information and requirements.

W a r n i n g

DISCONNECT

ELECTRIC

POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screw- driver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

2

41949-01 3/29/2006

05-HF-011-EngS_3.29.06.indd 2

3/29/06 8:57:48 AM

Image 2
Contents Installation I d e Preventative Maintenance Before Installation X2 DRemove the motor/blower from the housing A11 A12A13 A14A15 A21 A22 A18A19 A20B13 B11B12 B15B20 B17B19 B18B24 B22B23 B26 B27C13 C12 Existing Construction accessible from aboveC11 C14C19 C15C16C17 C20C23 C21C22 C28 C25C26 C29D12 Existing Construction accessible only from belowD11 D13 D14D19 D16D17 D18 D20Attaching the Grille D22D23 29/06 85829 AM Trouble Shooting SolutionWarranty Limited WarrantyDesde Í a S t a l a c i ó nPrecaución Antes de la instalación Verifique todos losRetire el motor/soplador del alojamiento Construcción nueva fijación a la viga Conecte los alambres como se muestra A21 Vaya al pasoConstrucción nueva suspendido entre vigas De pulgApriete los tornillos B26 B23C11 Ventilador Existente SIN Ventilador Existente Construcción existente accesible desde arribaTaladre un agujero en el centro de cada perfil Apriete los tornillos del aliviador de tensiones Vaya al paso En la página 37 para Fijar la rejilla D13 Construcción existente accesible sólo desde abajoD20 Fijación de la rejilla 29/06 85949 AM Solución de problemas SoluciónGarantía Garantía Limitada