Fujioh BUF-02, BUF-01 Safety Instructions, To Reduce the Risk of FIRE, USE only Metal Ductwork

Page 2

SAFETY INSTRUCTIONS

Before installation and operation, read these instructions carefully and use this product only in the manner described by the manufacturer in the operation manual.

The signal words shown below are used to alert you to potential personal injury and property damage hazards.

There are three hazard classifications based on potentially dangerous situations.

Obey all safety instructions that show these symbols to avoid possible injury, death and property damage.

WARNING:

CAUTION: CAUTION:

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

WARNING

1.TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a)Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b)Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

2.To reduce the risk of fire or electric shock, do not use this product with any solid-state speed control device.

3.TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a)Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

b)Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and The American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

c)When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

d)Ducted fan must always be vented to outdoors.

4.TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

5.This unit must be grounded.

6.Install this range hood to a liner. Check that the hood is correctly installed, since incorrect installation could result in the range hood becoming detached and falling off.

7.Connect only to an AC120 Volt power source or the range hood could result in fire, electric shock, and damage.

2

Image 2
Contents Range Hood Safety Instructions To Reduce the Risk of FIRE, USE only Metal DuctworkPage Size & Dimensions Name of PartsRange Hood Location Installation PreparationInstallation Range Hood Mounting Fasten all screws and nuts evenly Connecting Power Supply Wires Installation Final Assembly and Check AssemblyCircuit Diagram Explanation to the END User1U030584

BUF-01, BUF-02 specifications

The Fujioh BUF-01 and BUF-02 are innovative and high-performance gas hobs designed to meet the needs of modern kitchens. Both models stand out not only for their sleek aesthetics but also for their advanced features and technologies that enhance cooking efficiency and safety.

One of the main features of the BUF series is their powerful burners. The BUF-01 is equipped with a high-efficiency burner that delivers rapid heat for boiling and frying, making meal preparation quicker than ever. The BUF-02 boasts multiple burner settings to accommodate various cooking styles, ensuring that home cooks can enjoy versatility in their culinary endeavors. The interactive gas controls allow users to easily adjust flame levels, providing precise heat management.

Safety is a key consideration in the design of the BUF-01 and BUF-02. Both models come with built-in flame failure safety devices, which automatically shut off the gas supply if the flame is extinguished. This feature not only provides peace of mind but also promotes a safer cooking environment, especially for families with children.

Another notable characteristic of the Fujioh BUF series is their easy-to-clean design. The hobs are equipped with a smooth surface that resists stains and spills, making maintenance a breeze. The removable grates and burners allow for thorough cleaning, ensuring that the appliances not only look good but also function optimally over time.

Fujioh has also incorporated innovative technology into the BUF-01 and BUF-02 to enhance user experience. The ergonomic design of the knobs allows for effortless operation, and the integrated ignition system makes lighting the burners simple and efficient. The hobs are compatible with a wide range of cookware, including traditional pots and modern induction-compatible pans, making them versatile additions to any kitchen.

Both models reflect Fujioh's commitment to quality and performance. They are crafted from durable materials that resist corrosion and wear, ensuring longevity in even the busiest kitchens. With their combination of power, safety features, and easy maintenance, the Fujioh BUF-01 and BUF-02 gas hobs are excellent choices for anyone looking to elevate their cooking experience while maintaining style and functionality in the kitchen.