White Rodgers 36C01 Main Piping Connections, Pilot GAS Connection, Installation

Page 3

MAIN PIPING CONNECTIONS

NOTE

All piping must comply with local codes, ordinances, and/or national fuel gas codes.

1.Turn off electrical power to the system at the fuse box or circuit breaker. Also turn off the main gas supply.

2.If replacing an existing valve, disconnect all plumbing and electrical connections from the old control.

3.The control may be installed in any orientation except upside down. The arrow on the valve indicates the direction of gas flow through the control.

4.You should use new pipe that is properly chamfered, reamed, and free of burrs and chips. If you are using old pipe, be sure it is clean and free of rust, scale, burrs, chips, and old pipe joint compound.

5.Apply pipe joint compound (pipe dope) or teflon tape that is approved for all gases, only to the male threads of the pipe joints. DO NOT apply com- pound or teflon tape to the first two threads (see fig. 1 for typical piping connections).

6.If you are using a vise or open-end wrench to hold the valve while installing piping, do not tighten exces- sively, as this may damage the valve.

7.If additional clearance for the gas cock knob is re- quired when installing the new valve in an existing system, rotate the knob to the position between ON and OFF. Depress the knob while turning the valve. The knob will depress only while in this position.

8.See SYSTEM WIRING when making electrical con- nections. After all gas and electrical connections are completed, turn gas on and check for gas leaks with leak detection solution or soap suds. Bubbles forming indicate a leak. SHUT OFF GAS AND FIX ALL

LEAKS IMMEDIATELY.

PILOT GAS CONNECTION

Install fitting into pilot gas outlet (see fig. 2), turning until finger-tight. Insert clean, deburred tubing all the way through the fitting. While holding the tubing securely, slowly tighten fitting until you feel a slight “give”. Tighten the fitting an additional 112 turns.

INSTALLATION

Drop

Horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve

 

 

NOTE:

 

 

Riser

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Always Include

 

 

 

 

 

3 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A Drip Leg In Piping

 

 

 

 

 

minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tubing Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

 

 

 

 

 

 

 

 

 

 

 

Gas Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Riser

Horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

3 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minimum

minimum

 

 

Piped Gas

Piped Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1. Typical gas valve piping

Pilot gas

PRESS

outlet

PILOT

 

TAP

Gas outlet

 

Figure 2. Gas valve side view

3

Image 3
Contents Description SpecificationsPrecautions Installation Main Piping ConnectionsPilot GAS Connection System Wiring Pilot GAS AdjustmentPressure Regulator Adjustment For Your Safety Read Before Lighting Pilot Lighting Instructions Precautions

36C01 specifications

The White Rodgers 36C01 is a multi-stage technology thermostat designed to enhance energy efficiency and comfort in residential heating and cooling systems. As a product of the well-established White Rodgers brand, it combines innovative features with user-friendly controls, making it an excellent choice for homeowners looking to optimize their indoor climate management.

One of the standout features of the 36C01 is its compatibility with a variety of heating and cooling systems, including gas furnaces, electric heat pumps, and central air conditioning units. This versatility ensures that users can implement the thermostat in various environments, whether they're upgrading an existing system or installing a new one.

The 36C01 boasts a sleek design with a digital display that makes it easy to read and adjust settings. The intuitive buttons and menu system allow users to program the thermostat with ease, enabling the setup of specific heating and cooling schedules for different times of the day. Users can enjoy customized temperature settings that adapt to their lifestyles, promoting energy savings while maintaining comfort.

One of the key technologies incorporated into the 36C01 is its precision temperature control. This feature enhances comfort by reducing temperature swings and allowing for consistent indoor conditions. The thermostat is also equipped with a reliable temperature sensor, ensuring that the displayed and actual room temperatures are closely aligned.

Additionally, the 36C01 includes a battery backup system, which ensures that settings are retained in the event of a power outage. This reliability provides peace of mind for homeowners who want assurance that their heating and cooling schedules will remain intact.

Moreover, the White Rodgers 36C01 is designed with energy efficiency in mind. Its programmable features encourage users to settle on energy-saving temperature settings during peak hours. Coupled with the precision control, this can significantly reduce energy consumption, leading to lower utility bills.

In summary, the White Rodgers 36C01 thermostat is an advanced yet user-friendly solution for managing home heating and cooling. Its compatibility with various HVAC systems, precision temperature control, intuitive interface, and energy-saving features make it a valuable addition to any home, enhancing both comfort and efficiency. With this thermostat, homeowners can confidently take charge of their indoor climate, enjoying a perfect balance of comfort and energy conservation.