SOMETHING NOT WORKING
Important: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or installation a charge will be made, even if the appliance is under guarantee.
Before contacting your local Service Force Centre, check the following points:
| Symptom | Solution |
|
|
|
| No power to the appliance | Check there is power at the socket. |
|
|
|
|
| Check there is not a power cut by checking the |
|
| household lights. |
|
|
|
|
| Check the fuse has not blown. |
|
|
|
| The light does not come on | Ensure that the bulb is correctly fitted. |
|
|
|
|
| Replace the bulb if it has blown. |
|
|
|
|
| Check the door light switch is not jammed. |
|
|
|
| The temperature in the fridge or freezer section is | Check the thermostat control knob in the fridge is |
| too high | turned to the correct setting relative to ambient |
|
| conditions. |
|
|
|
|
| Check the ambient temperature is within the |
|
| appliance’s operating limits, please refer to the |
|
| installation section in this instruction book. |
|
| Relocate the appliance if necessary. |
|
|
|
| The freezer door will not open | Has door just been opened? If so leave for a few |
|
| minutes to allow the air pressure to equalise. |
|
|
|
| The compressor runs continously | Adjust the thermostat control knob to give correct |
|
| temperature control. See “Setting the temperature”. |
|
|
|
|
| Check that the doors are closed. |
|
|
|
|
| Large quantities of food have recently been placed in |
|
| the cabinet and/or door is frequently opened. |
|
|
|
|
| Check that air ventilation is not obstructed. |
|
|
|
| Excessive frost and ice has built up | Ensure the doors are not left open. |
|
|
|
|
| Check that nothing is preventing the doors from |
|
| closing. |
|
|
|
|
| Is the door gasket intact and clean. |
|
|
|
|
| Has advised periodic defrosting been carried out. |
|
|
|
| Noise | Refer to normal operating sounds. |
|
|
|
| Water under the salad crispers | Check the drain hole is not blocked. (see |
|
| Maintenance and Cleaning). |
|
|
|
Low room operation
During prolonged periods of low room temperatures,ie;10°C and lower, the compressor on single compressor fridge freezer can remain inoperative during this time .
This is due to the air temperature within the refrigerator compartment being maintained at 6°C or under thus not calling the thermostat to energise the compressor .
10