Toastmaster E17UAC-INS, E6UAC-INS manual Service Specifications E17UAC, Trouble Shooting

Page 7

SERVICE SPECIFICATIONS – E17UAC

The Heater Proofer is an aluminum transport cabinet with heaters to function as a hot food holding cabinet, and/or as a proofing cabinet.

The heater, or heat drawer, is slid into place on the floor of the cabinet. An electrical socket on the back of the drawer is provided to accept the supplied power cord, which is plugged into the drawer through an access hole in the back of the cabinet.

The main power switch on the front of the drawer, when switched “ON”, will turn on the light in the switch and turn on the air circulating fan in the drawer. The circulating fan will operate continuously while the unit is “ON”.

The thermostat control knobs are mounted to the left and right of the heat/proof switch. The left thermostat knob controls the heat in the cabinet from 1 (low heat: approximately 80°F) to 9 (high heat: approximately 175°F). The right thermostat knob controls the humidity from 1 (approximately 20% relative humidity) to 9 (in excess of 100% relative humidity). Average setting will be approx. 6 (approximately 85% relative humidity).

TROUBLE SHOOTING -

Caution: Before disassembling unit, electrical power must be disconnected by unplugging the unit. Failure to unplug the unit prior to servicing may result in electrical shock.

Each unit is shipped with an instruction manual to be used as a reference guide for all service areas. The manual shows a picture of the drawer, showing the location of electrical components and a description of each. If the unit does not operate correctly, or malfunctions for any reason, the following checklist should provide a solution.

1)Check to make sure cord set is firmly plugged into the wall outlet.

2)Check circuit breaker of wall outlet and reset if necessary.

3)Remove heat drawer from cabinet. Remove bottom cover of drawer. Visually inspect for:

a)Loose or disconnected wires

b)Black marks or burning on any components

c)Loose heating elements.

4)If any burn marks or discoloration of wires is note on any components along with all wires attached to damaged components must be replaced.

5)If heater element is loose, or if it has broken loose from mounting tabs, the wires will short out on the Metal, causing permanent damage. Both the element and main power switch (with wires on switch) must be replaced.

PAGE 5

Image 7
Contents E17UAC E17UAC-INS E6UAC E6UAC-INS Model E17UAC Unpacking General InformationHeat Thermostat Operating InstructionsHumidity Thermostat Parts List for E17UAC E17UAC Trouble Shooting Service Specifications E17UACWarranty Exclusions and Limitations Equipment Warranty