COUNTERTOP FOODWARMERS
SECTION V
Fusing
This warmer draws 4.0 amps at 120 Volts. Be sure the circuit to which it will be connected is adequately wired and fused to accept this added load.
SECTION VI
A. Preventive Maintenance
Observe well for lime
B. Purpose of each electrical component.
ON/OFF Switch - Turn on power to device. Signal light glows to show power is on.
Operating Thermostat - (Thermo Disc Type for 1529), (Infinite Switch for 1523 and 1527) Cycles heating unit on and off to maintain an average temperature of 170 (filled with water level mark in well.)
Heating Unit - Offers heat to bottom of well.
Audible Buzzer - Signals operator to fill well with water immediately.(1529 Models).
TROUBLE SHOOTING INFORMATION
DURING NORMAL OPERATION (WATER IN WELL)
| Symptom | Possible Cause |
| |
1. | No Signal Light | No incoming power. | ||
|
| No Heat | Switch Defective. | |
|
| No Buzzer | Wire off. |
|
2. | No Signal Light | Switch light defective. | ||
|
| Heats |
|
|
|
|
|
|
|
3. | Signal Light Glows | Wire off. | ||
|
| No Heat | Heating unit defective. | |
|
|
| Operating thermostat defective. | |
|
|
|
|
|
4. | Signal Light Glows | |||
|
| Buzzer Sounds |
|
|
|
| ABNORMAL OPERATION (NO WATER IN WELL - EVAPORATED DRY) | ||
|
|
|
| |
| Symptom | Possible Cause |
| |
1. | Signal Light Glows | Buzzer defective. | ||
|
| No Buzzer | ||
|
|
|
|
|
PAGE4 |
| Toastmaster ® |