7.0Setting the Timer

7.1Setting the Timer

The Electro-Mechanical Timer allows the central heating system to be set every 15 minutes.

Using the three position switch the timer will allow either constant operation, timed operation or central heating off.

Move the switch button by sliding to the desired position.

Three position switch (Fig. 6)

Constant (Top position): The heating will be on constantly irrespective of the position of the tappets.The heating will be controlled by the main thermostat on the appliance and/or any external controls.

Timed (Central position): The heating will operate according to the position of the tappets and be controlled as above.

0Off (Bottom position): No central heating. Domestic hot water will operate on demand.

To set the time of day

Turn the timer outer bezel clockwise, to align the pointer with the correct time to the nearest 15 minutes ensuring that A.M./P.M. is considered. Do not at any time attempt to turn the bezel anti-clockwise.

To set the timed heating program

Decide which times of the day the central heating is required.

The heating will operate when the white tappets are set to the outer edge of the bezel.

To ensure the heating stays OFF set the required tappets inwards towards the centre of the bezel.

Each tappet represents 15 minutes.

For example: If the heating is not required between

10 A.M. and 11 A.M. the four tappets anticlockwise from the 10 A.M. will be set inwards (Fig. 7).

NOTE: The integral timer may have been removed and replaced with a blanking plate depending on the type of external controls used. In this event please consult your installer for details.

10© Baxi Heating UK Ltd 2012

Image 10
Contents User Guide Contents 0086Domestic Hot Water Temperature Control Central Heating Temperature ControlQuick Reference Guide Troubleshooting Is the Room Thermostat if Is the Integral Timer on and calling for heat ?Fitted set high enough ? Central Heating System Pressure Repressurising the SystemTo Re-Pressurise the System Clearances Fault Indication Table of Error CodesCare of the Boiler Benchmark Commissioning Checklist Installation, Commissioning, Service & RepairLegislation Setting the Timer Setting the TimerEmergency Faulty boilerIf you smell gas Warranty & Service Please complete the boxes below