ERD60
Revised | 60” Wide, |
| PLANNING | |
Epicure® Range | 1/2 | GUIDE | ||
06/25/08 |
1 9/16" (40mm)
28 1/2" (724mm) 27" (686mm)
26" (660mm)
24 3/8" (619mm)
When Backguard and Side Panels are
removed, the overall depth decreases by 1" (25mm)
Handle
Front Edge of Bullnose
Face of Control Panel/Oven Door
Rear of Control Panel/Oven Door
6” (152mm) Backguard
37”
(940mm)
to
353/4"
(908mm)
warning
◊Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
◊This appliance must be installed in accordance with the accompanying installation instructions.
Finished Side Panel
60" (1524mm)
6" (152mm) Backguard
Accessory 3” (76mm) Side Panels
(Dacor Model No. AESP03)
erd/eGR30, erd60 overall dimensions
side view
|
| Power Cords |
| Factory installed 3/4” regulators | ||
|
|
|
|
| (1/2” supply ok) | |
|
|
|
| rear view |
| |
|
|
|
|
|
|
|
|
| Total |
|
|
|
|
Dacor® | Dedicated Circuit* | Connected |
| Gas | Manifold | Min. Gas Supply |
Model No. | Required | Load |
| Type | Pressure | Pressure |
ERD60 | 240 Vac, | 4.1 kW |
| Natural | 5” Water Column | 6” Water Column |
ERD60LP |
| Liquid |
|
| ||
30 Amp (Breaker) X2 | (21Amp) X2 |
| 10” Water Column | 11” Water Column | ||
|
| Propane | ||||
|
|
|
|
|
|
*Two separate dedicated circuits are required, one for left and one for the right side of the range.
Electrical AND GAS Supply Requirements
NOTES:
1.Utilities may be located in the lower left corner of the adjacent right cabinet. (Recommended)
2.Contact your local building department to verify compliance with local code interpretation.
3.Two electrical circuits and gas supplies required.
Web: http://www.Dacor.com | Specifications are subject to change without notice. | 5.7 |