Giant LP122A operating instructions Installation Instructions, Important Operating Conditions

Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

1.The pump should be installed flat on a base to a maxi- mum of a 15 degree angle of inclination to ensure optimum lubrication.

2.The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 1600 F, it is important to insure a positive head to the pump to prevent cavitation. See NPSH curve for LP122A Series/ LP123 pumps.

3.The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

4.Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsation. Dampen- ers can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.

5.Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction designated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3 and 6.

6.Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavita- tion will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.

LP122A/LP123

NPSHR Curve

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1.Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.

Use SAE 90 Industrial gear oil (Giant’s p/n 01154)

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

2.Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

3.Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

4.Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.

NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600

2

Image 2
Contents LP122A/LP122A-4000/LP123/LP255 Installation Instructions Important Operating ConditionsHorsepower Information Pulley InformationExploded View LP122A/LP122A-4000/LP123/LP255 LP122A/LP122A-4000/LP123/LP255 Parts List Partno DescriptionSpecifications Model LP255 Pump System Malfunction LP122A/LP122A-4000/LP123/LP255 Repair Instructions To Reassemble Proceed AS Follows LP122A/LP122A-4000/LP123/LP255 Torque Specifications LP122A/LP123/LP255 Dimensions mm LP122A-4000 Dimensions mm Giant Industries Limited Warranty

LP122A specifications

The Giant LP122A is a versatile and powerful bicycle renowned for its robust design and advanced technology, making it a popular choice among cycling enthusiasts and casual riders alike. This bike combines quality materials, innovative engineering, and user-friendly features, ensuring an enjoyable riding experience for all.

One of the standout features of the Giant LP122A is its lightweight aluminum frame. With a focus on durability and strength, the aluminum construction offers excellent resistance to corrosion while maintaining a low overall weight. This ensures that riders can navigate various terrains with ease, making it ideal for both urban commuting and off-road adventures. The geometry of the frame is designed to provide a comfortable riding position, promoting stability and control during long rides.

The LP122A is equipped with a high-performance drivetrain, featuring a smooth-shifting system that allows for quick and precise gear changes. This feature is especially beneficial when tackling steep hills or navigating tricky paths, as riders can easily adjust their speed and cadence. The bike typically incorporates quality components from reputable brands, ensuring reliability and longevity.

Another key characteristic of the Giant LP122A is its enhanced suspension system. The front suspension fork absorbs shocks and bumps, providing a smoother ride on rough terrain. This is particularly important for mountain biking, where uneven surfaces can pose challenges. Additionally, the suspension settings are often adjustable, allowing riders to customize their experience based on personal preferences and riding conditions.

Braking performance is crucial for safety, and the LP122A excels in this aspect with responsive disc brakes. These brakes offer superior stopping power, ensuring that riders can confidently handle various speeds and descents. Disc brakes provide consistent performance in wet or muddy conditions, making this bike suitable for all-weather riding.

In terms of aesthetics, the Giant LP122A boasts a modern design with vibrant color options that appeal to a broad range of riders. With its sleek lines and attention to detail, the bike not only performs well but also looks stylish on the road or trail.

Overall, the Giant LP122A stands out as an exceptional bicycle that combines advanced technology, robust features, and user-friendly characteristics. Whether for commuting, recreational riding, or tackling tough trails, the LP122A offers a reliable and enjoyable option for cyclists seeking performance and comfort.