CMA Dishmachines GL-X manual Maintenance, Timer assembly, Cam Adjustment

Page 11

Maintenance

4. Maintenance

The maintenance procedures detailed in this section are to be performed by qualified personnel.

4.1.Timer assembly

The standard timer assembly consists of a (2 minutes per revolution) motor turning a common shaft, which, in turn, rotates eight cams. As the cams rotate, they control various functions and the sequence of the operational cycle.

A label on the timer assembly identifies the individual function of each of the 8 cams. Cams 1 through 8 are positioned from left to right beginning with the “START” cam (cam 1).

START

DET.

DRAIN

FLUSH

SANI.

RINSE

MOTOR PAUSE

HEATER

Timer Assembly Label

Except for cams 1, and 3, all other cams can be user adjusted. The cam positions are all set at the factory and only the cams controlling the chemical pumps (cams 2, 5 & 6) should ever need adjusting. Each micro switch on the timer assembly is turned on and off by the cam its actuator rides on. For all of the cams, except cams 1, 7 and 8, its corresponding switch is ON when its actuator is down in the cam groove. (Cams 1, 7 and 8 are reverse acting and are turned ON when the micro switch actuator is up out of the groove.) Opening the groove of any cam other than cams 1, 7 or 8 will increase the amount of time that the micro switch is held ON. The cams are slip-fit and a cam adjustment wrench is provided (a small screw driver or the edge of a table knife can also work to adjust the cams).

4.1.1. Cam Adjustment

The two sides of each cam connect to the shaft with a slip-fit so all cam adjustments are made by rotating one side of the cam on the shaft to either increase or decrease the size of the cam groove.

1.Turn off the circuit breaker providing power to the machine before accessing the timer assembly.

Caution: One of the terminals on the main power switch remains “hot” even when the machine’s main power switch is turned off—so turn the power off at the circuit breaker.

2.Remove the two screws securing the front lower panel.

3.Using the timer assembly label, determine which cam is to be adjusted. Double check by counting over from cam 1 to the cam to be adjusted.

4.Determine which edge of the cam groove to be adjusted is the leading edge (contacts the limit switch actuator first when the shaft is rotating) and which edge of the groove is the trailing edge. The leading edge of the cam groove determines when in the cycle the control action begins and should not be changed.

5.Adjust the trailing edge of the cam groove by rotating the appropriate side of the cam in the proper direction to either increase or decrease the cam’s groove; resulting in increasing or decreasing the total time that switch will be held ON.

MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.00A –08/04/05

10

PAGE

Image 11
Contents Model GL-X Table of Contents GL-X Specifications100 110 GL-X Operational CyclePage Introduction to the GL-X Getting StartedPost Instructions Receiving and InstallationElectrical PlumbingInstallers Checklist General Initial SetupOperation Pump Cavitation Proper FillingWater Pump Cam Adjustment MaintenanceTimer assembly Models GLX Technical Issue Cause Solution Quick service guideTroubleshooting Maintenance Maintenance Addendum for Machines Installed in the City of Chicago Appendix a Operator & Cleaning Instructions Electrical Diagram Electrical Diagram
Related manuals
Manual 19 pages 36.39 Kb