La Pavoni P3 manual Switching on, Troubleshooting Guide, Your DRINK…

Page 6

SWITCHING ON

After having followed all the instructions of installation, it is possible to turn on the machine through the light switch situated on the frontal side of the electric panel.

At the switch on of the machine, it appears on display for a brief time the message of the version software, after that it will begin the heating of the boiler that will be visualized with the message" HEATING" that will be replaced, to reached tem- perature, from the flowing message". ….INSERT THE C REDIT AND SELECT

YOUR DRINK…”.

Note: it is advisable immediately to execute a manual washing after the switch on, to load with more facility the hydraulic circuit and the boiler. To do this, make reference to the" quick functions" at page 22.

Keyboard description

TROUBLESHOOTING GUIDE

The machine is provided with a program of self-diagnosis, that allows to visualize on the display the messages of breakdown or machine stopped :

ERROR GROUP 1

the coffee-group has not reached the “supply position” given by its right

 

micro switch. Check Fuses, group right micro switch, group motor,

 

electronic board..

ERROR GROUP 0

the coffee-group has not reached the “normal position” given by its left

 

micro switch. Check Fuses, group left micro switch, group motor, elec-

 

tronic board.

ERR. COFFEE FLOW

During espresso supplying, the board has not received signals from the

 

flowmeter. Check fuses, too fine coffee, coffee pump, coffee electro

 

valve, flowmeter, electronic board.

ERR. SOLUB.FLOW

During soluble supplying, the board has not received signals from the

 

flowmeter. Check fuses, soluble pump, soluble electro valve, flow-

 

meter, electronic board.

ERROR GRINDER 1

During the coffee grinding, the board has not received the signal given

 

by the doser-switch in the maximum time of 25 seconds. Check too

 

fine coffee, fuses, doser micro-switch, grinder motor, grinder blocked

 

by something hard, electronic board.

LACK OF WATER

The board doesn’t receive the signal from the float. Lack of water, float,

 

water container micro switch, electronic board.

ERROR BOILER 1

The board has not received the programmed value temperature from the

 

boiler probe in the maximum time of 15 minutes. Check safety thermo-

 

stat, boiler heating element, electronic board.

EMPTY GROUNDS!

The coffee grounds decounter has reached the programmed value.

 

Empty the grounds and execute the quick function nr.5.

ERROR EXECUTIVE

The board does not receive signals by the payment system, Executive or

 

MDB, programmed. Check payment system, cables, electronic board..

ERROR MIXER

the board has received too much current from the whipper motor used.

 

Check the whipper or clean the mixer.

All the alarms are deleted, once the trouble is solved, switching off the machine.

Pag. 6

Pag. 23

Image 6
Contents P3 / P3 Evolution Technical Characteristics Water Filter VA ONE-WAY ValveCV Flowmeter Pump ONE-WAY Valve C Boiler Water Flow Diagram Grinder Installation Electric ConnectionOn cabinet Electrical DiagramHydraulic Connection On small baseSwitching on Troubleshooting GuideYour DRINK… Frequent Menu Quick FunctionsProgramming ∙ SET Drinks ∙ SET Prices ∙ Counters & Amounts ∙ EventsSET Drinks 01-02-03-04-05-0 Sel.1SET Prices SOL.4 LIOF.SUG.VCounters & Amounts Free Mode COUNTERS&AMOUNTSReset COUNTERS? Total COUNTERS&AMOUNTSEvents Electrical OutputMain Menu SET TemperatureOptions Insert Password Payment SystemPayment System SET Temperature Options