opens, causing the water pressure to push the internal piston, you should be able to see the liquid travel the length of the tube.
4)Once the liquid as reached the back of the pump, turn the adjusting screw on the rinse pump clockwise all the way in and
The
DO NOT use sanitizer (chlorinated products, bleach) with this pump. It is not made to pump harsh chlorinated liquid. This will void warranty on the dishwasher.
Know Your Application.
When purchasing the detergent, it is important to specify what you want to wash. Most detergents sold on the market are good for regular soil
For any other request on
extension 611...
IMPORTANT
Remember to always use caution and protective gears whenever you are manipulating chemicals. They can burn the skin. Follow supplier’s instructions carefully.
SPECIFICATIONS
Peristaltic pumps for
Electronic regulation
G82
-max. delivery 0,6 l/h - silicone tube for rinse additive
-max. delivery 0,8 l/h - thermoplastic tube for detergent G152
-max. delivery 1,5 l/h - thermoplastic tube for detergent G202
-max. delivery 2,0 l/h - thermoplastic tube for detergent G252
-max. delivery 2,3 l/h - thermoplastic tube for detergent
230V 50/60Hz (24V by request)
*On request: Silicone tube
1 litre = 35.195 once
.55 ml/sec
30