Powermatic manual Troubleshooting the DT65 Dovetailer, Probable Cause Remedy

Page 24

Troubleshooting the DT65 Dovetailer

Trouble

Machine will not start/restart or repeatedly trips circuit breakers or blows fuses.

Probable Cause

Remedy

 

 

Machine not plugged in.

Verify machine is connected to power

 

 

Fuse blown, or circuit

Replace fuse, or reset circuit breaker.

breaker tripped.

 

 

 

Cord damaged.

Replace cord.

 

 

 

If the dovetailer overloads on the circuit breaker

 

built in to the motor starter, it takes time for the

Overload automatic reset

machine to cool down before restart. Allow unit to

has not reset.

adequately cool before attempting restart. If

 

problem persists, check amp setting on the motor

 

starter inside the electrical box.

 

 

 

Check the amp setting on the overload relay.

Dovetailer frequently trips.

Match the full load amps on the motor as noted on

the motor plate. If amp setting is correct then there

 

is probably a loose electrical lead or a failed

 

component. See below.

 

 

Building circuit breaker trips

Verify that dovetailer is on a circuit of correct size.

If circuit size is correct, there is probably a loose

or fuse blows.

electrical lead. Check amp setting on motor starter.

 

 

 

 

Go through all of the electrical connections on the

Loose electrical

dovetailer including motor connections, verifying

the tightness of each. Look for any signs of

connections.

electrical arcing which is a sure indicator of loose

 

 

connection or circuit overload.

 

 

 

If you have access to a voltmeter, you can

 

separate a starter failure from a motor failure by

 

first, verifying incoming voltage at 220+/-20 and

Motor starter failure.

second, checking the voltage between starter and

motor at 220+/-20. If incoming voltage is incorrect,

 

you have a power supply problem. If voltage

 

between starter and motor is incorrect, you have a

 

starter problem. If voltage between starter and

 

motor is correct, you have a motor problem.

 

 

 

If electric motor is suspect, you have two options:

Motor failure.

Have a qualified electrician test the motor for

function or remove the motor and take it a qualified

 

 

electric motor repair shop and have it tested.

 

 

 

Check to make certain all electrical connections

 

are correct and properly tight. The electrical

 

connections other than the motor are

Miswiring of the unit.

preassembled and tested at the factory. Therefore,

 

the motor connections should be checked as the

 

highest probability for error. If problems persist,

 

double check the factory wiring.

 

 

 

If the on/off switch is suspect, you have two

On/off switch failure.

options: Have a qualified electrician test the switch

for function, or purchase a new on/off switch and

 

 

establish if that was the problem on changeout.

 

 

24

Image 24
Contents Single End Dovetailer Warranty and Service Warranty PeriodTable of Contents Page Page Specifications Introduction DescriptionFeatures of the DT65 Dovetailer Terminology Contents of the Shipping Container UnpackingInstallation & Assembly Attaching Dust HoseInstalling Dust Chute Dust CollectionGrounding Instructions Volt Operation Extension cordsAir Connection Adjustments Clamping CylindersClamping Pressure Locking HandlesTemplate Bar Indication Template Fixed ChaserHorizontal and Vertical Fences View from rear of machine Buffer Pads Cutter HeightMortise Depth Thickness of Tenon Cut Tightness of Mortise/Tenon FitDrive Belt Tension Replacing cutterOil Output Operation Keep fingers clear of clamping cylindersPage Preventing Chip Out Dovetails in PlywoodMaintenance LubricationTroubleshooting the DT65 Dovetailer Probable Cause RemedyTrouble Replacement Parts Parts List Base AssemblyBase Assembly Parts List Hold-Down Assembly Hold-Down Assembly Parts List Headstock Assembly LM25UUDT65-258 Headstock Assembly Parts List Cabinet Assembly Electrical Connections Page New Sanford Road LaVergne, Tennessee Phone