Thermo Products OH6FX072DV4 operation manual Adjustment Of Heat Input Rate

Page 6

ii.CARBON DIOXIDE (CO2) OR OXYGEN (O2): Take a CO2 sample from flue passageway. It is possible to achieve readings of up to 14% CO2 (or 2% O2 ), but it is better to have a slightly lower CO2 (or higher O2) reading with zero smoke measured. To achieve a lower CO2 reading, open the air band, or shutter, on the burner until zero smoke is measured.

For example, if a 13% CO2 (or 3.5% O2) is recorded at a trace of smoke, open the air shutter until zero smoke is measured with a 12% CO2 (or 4.5% O2).

Adjustment of the burner to achieve a slightly lower CO2 reading is recommended, although it slightly reduces combustion efficiency, to keep the heating system within normal operating conditions though external conditions may vary. Some “out-of-spec” conditions which may adversely affect burner performance are, low oil supply temperature, dirty (contaminated) oil, low heating content (BTU/gal) oil, cold heat exchanger surfaces, and downdraft conditions. By adjusting the burner in this manner, an operational tolerance is established allowing the burner to function well, even under less than ideal conditions. This results in less service and maintenance during a heating season.

iii.FLUE GAS TEMPERATURE: The flue gas temperature will vary to some extent depending on the heat input rate, duct design, and the amount of air flow across the heat exchanger. The suggested minimum net flue gas temperature is 350ºF, and the maximum gross flue gas temperature is 500ºF. The lower the flue gas temperature, the higher the heating efficiency. However, stack temperatures under 350ºF may result in condensation of water vapor in the flue gases, which in turn promotes corrosion of the heat exchanger.

iv.TEMPERATURE RISE: Temperature rise is equal to the supply air temperature minus return air temperature. Under steady state operating conditions, the temperature rise across the heating section should be approximately 65ºF. A higher temperature rise will slightly lower the heating efficiency. A lower temperature rise will slightly raise efficiency, but may cause condensation.

The supply air temperature should be measured in the supply air trunkline approximately 12 inches downstream of the supply air outlet of the appliance.

NOTICE: Minimum temperature rise is 50ºF.; maximum temperature rise is 80ºF.

k.After final adjustments are completed, tighten all screws to fix the positions of the burner air band.

l.Check for the presence of oil leaks. Correct any oil leaks found.

m.Reassemble the burner compartment cover.

n.Start and stop the unit several times while checking for proper ignition of the burner. The flame should ignite and stabilize without any significant rumbles or pulsations.

1. Adjustment Of Heat Input Rate:

This appliance was shipped from the factory with one, fixed, main burner nozzle sized to produce the low-fire input rate using no. 2 fuel oil at the pump pressure shown on the rating label. The input rate can be changed to the high-fire by switching to the larger burner nozzle and increasing the pump pressure.

The main burner oil nozzles for this unit were selected based upon the following assumed characteristic values of the fuel oil suitable for use with this appliance design:

For no. 2 distillate fuel (domestic heating) oil having a higher heating value of 140,000 BTU per gallon and a specific gravity of 0.88 @ 60ºF. (or “gravity” of 30º API @ 60ºF.).

It is possible to make minor adjustments to the heat input rate by adjusting the pump pressure. Sizeable changes in input rate (especially reductions) should be made by replacing the burner nozzle. To adjust the pump pressure to the main burner:

6

Image 6
Contents For 2 Stage Riello Burner For USE with Model OH6FX072DV4Stage Firing Rates Capacity Nozzle Size Input Rate Effective Combustion Head Setting for 2-STAGE Riello Burner Mounting the 2-STAGE Riello BurnerAIR Damper Adjustment Turn to the Right Sign +Turn to the Left Sign 1st Stage Adjustment 2nd Stage AdjustmentAdjustment Of Heat Input Rate

OH6FX072DV4 specifications

The Thermo Products OH6FX072DV4 is a high-efficiency heating system designed to meet the needs of modern residential spaces. With its innovative technology and robust construction, this unit excels at providing reliable warmth while optimizing energy consumption.

One of the standout features of the OH6FX072DV4 is its Energy Star certification, indicating that it meets stringent energy efficiency guidelines set by the U.S. Environmental Protection Agency. This certification not only reflects the unit's ability to reduce energy costs but also minimizes the overall environmental impact of heating a home.

The OH6FX072DV4 employs advanced multi-stage heating technology, allowing it to adjust output based on the specific heating requirements of each room. This means that it can provide consistent warmth during the coldest months without overworking the system. The multi-stage operation also contributes to quieter operation levels, making it a preferable choice for homeowners seeking a peaceful living environment.

Another critical technology integrated into the OH6FX072DV4 is its variable-speed blower motor. This feature enhances temperature regulation by enabling the unit to operate at different speeds depending on the demand for heat. As a result, users experience better airflow and humidity control, leading to increased comfort levels throughout the home.

The OH6FX072DV4 also incorporates a user-friendly digital thermostat that simplifies temperature adjustments. With its programmable settings, homeowners can set schedules that align with their lifestyle, ensuring the home remains warm when needed while conserving energy during unoccupied periods.

In terms of safety and durability, the THermo Products unit is constructed with high-quality materials designed to withstand various weather conditions, ensuring a long service life. Its built-in safety mechanisms, including automatic shut-off features, protect against overheating and other potential hazards, giving users peace of mind.

Moreover, the OH6FX072DV4 features compatibility with smart home systems, allowing users to control their heating remotely via smartphone apps. This connectivity not only allows for convenient adjustments but also supports energy-saving practices, as users can monitor and modify their heating usage in real-time.

In conclusion, the Thermo Products OH6FX072DV4 combines efficiency, advanced technology, and user-friendly features to provide an outstanding heating solution for households. Its commitment to energy conservation, durability, and safety ensures it remains a leading choice for homeowners seeking to enhance their home's comfort during cold weather.