HARDWARE REQUIREMENTS

Processors Supported

DECstation:

DECstation 2100, DECstation 3100, DEC-

 

station 3100s, DECstation 5000 Model 200,

 

DECstation 5000 Model 200CX, DECstation

 

5000 Model 200PX, DECstation 5000 Model

 

200PXG, DECstation 5000 Model 200PXG

 

TURBO

DECsystem:

DECsystem 3100, DECsystem 5000 Model

 

200, DECsystem 5100, DECsystem 5400,

 

DECsystem 5500, DECsystem 5810, DEC-

 

system 5820, DECsystem 5830, DECsystem

 

5840

Processors Not Supported

Processors not listed above are not supported.

ULTRIX Mail Connection does not support DECsys- tem 5810 or DECsystem 5820. Refer to the ULTRIX Mail Connection Software Product Description (SPD 29.05.xx) for additional support information.

Other Hardware Required

A terminal-interface is required. See the Optional Hard- ware section for supported devices.

Disk space required for installation:

Uniplex II Plus, Base I

13.3Mb

Uniplex II Plus, Base II

13.0Mb

Advanced Office System

3.7Mb

Advanced Graphics System

3.5Mb

Additional Dictionary Pack

33.0Mb

Disk space required for permanent use:

Uniplex II Plus, Base I

13.3Mb

Uniplex II Plus, Base II

13.0Mb

Advanced Office System

3.7Mb

Advanced Graphics System

3.5Mb

Additional Dictionary Pack

33.0Mb

Other file systems: Space required for storage of word processing, spreadsheet, database, calendar and other normal data files.

The above sizes are approximate; actual disk space re- quired is dependent upon system environment, config- uration and software options.

A TK50 or TK70 device is required for software instal- lation.

OPTIONAL HARDWARE

The following terminals have been tested:

Character only: VT100, VT220, VT240, VT320, VT330, VT340, DECterm

High-resolution and character: VT240, VT330, VT340

Uniplex includes support for ReGIS on: VT240, VT330, VT340

The following printers have been tested:

Character mode: LA75, LN03 PLUS, LN03R PostScript®, LPS40

High-resolution and character: LA75, LN03 PLUS, LN03R PostScript, LPS40, LJ250

Plotters (graphics only): LVP16

Note: The LN03 PLUS requires the LN03-IC font car-

tridge.

SOFTWARE REQUIREMENTS

For Systems Using Terminals:

ULTRIX Operating System V4.1 (SPD 26.40.xx)

February 1991 AE-PE3UB-TK

Image 7
Contents February 1991 AE-PD1GB-TK Software Product DescriptionDescription Uniplex II PlusSPD Uniplex Business Software for Ultrix on RISC, Version 7.00cUniplex Advanced Office System Uniplex Advanced Graphics Hardware Requirements InstallationSoftware Product Services Software WarrantyPage QB-YQDA8-VE February 1991 AE-PE3UB-TK System Support AddendumOther Hardware Required Optional HardwareSSA 32.83.01-A Optional SoftwareGrowth Considerations Distribution Media

SPD 32.83.01 specifications

The 2Wire SPD 32.83.01 is a state-of-the-art surge protection device designed to safeguard a wide range of electronic equipment from voltage spikes and transients. This essential piece of equipment is particularly popular among businesses and homeowners that rely on sensitive electronics, such as computers, home theater systems, and industrial machinery.

One of the standout features of the 2Wire SPD 32.83.01 is its high surge current capacity. It is engineered to handle substantial voltage surges often caused by lightning strikes, power outages, and other electrical anomalies. With a surge current rating that meets or exceeds industry standards, this device helps ensure the protection of vital electronic apparatuses, thereby extending their lifespan and reducing repair costs.

The technology employed in the 2Wire SPD device is noteworthy as it utilizes advanced metal oxide varistor (MOV) technology for surge absorption. MOVs are known for their rapid response times and ability to clamp excessive voltage levels, providing reliable protection. Additionally, the device features thermal fuses that offer enhanced safety by disconnecting the MOV when it has reached its end-of-life condition, preventing further risk to attached equipment.

In terms of installation, the 2Wire SPD 32.83.01 is designed with user convenience in mind. It features a compact design that allows for easy mounting on standard electrical panels, ensuring that users can effortlessly integrate it into their existing electrical infrastructure. Furthermore, the mounting hardware included with the device enhances ease of installation while ensuring stability and reliability.

Another key aspect of the 2Wire SPD is its status indicator lights, which provide immediate visual feedback about the operational status of the device. These indicator lights inform users when the device is functioning optimally or if any issues need to be addressed. This feature significantly enhances user experience, as it simplifies monitoring and maintenance.

The durability and reliability of the 2Wire SPD 32.83.01 are complemented by its compliance with various industry certifications, giving users confidence that they are investing in a quality product. Whether for residential or commercial use, the 2Wire SPD 32.83.01 offers robust surge protection solutions that prioritize both safety and performance. Ultimately, its blend of advanced technology, robust installation options, and clear user indicators make it a preferred choice in the realm of surge protection devices.