Filter Performance Data Sheet
Model Number 5231JA2006E
Use with replacement cartridge 5231JA2006E
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a
concentration less than equal to the permissible limit for water leaving the system, as specified in NSF/ANSl 42.
System tested and certified by NSF International against NSF/ANSl Standard 42 for the reduction of Chlorine, Taste and Odor and Nominal Particulate Class III.
|
|
|
|
|
|
|
|
| Max. |
|
|
Contaminant | Average | Influent Challenge | Product | Average % | NSF Reduction | Effluent | Min. % | NSF | |||
Reduction | Influent | concentration. | Units | Water | Reduction | Requirements | mg/L | Reduction | Test | ||
apply to each | row |
|
|
|
|
| |||||
Particulate |
|
|
|
|
|
|
|
|
| ||
Class | I Particle size: | 5600000 | At least 10 000 | 833333 | 93.2 | _>85% | 470000 | 91.6% | |||
>0.5 | to | <1 um |
| particles/ml |
|
|
|
|
|
|
|
Chlorine | taste and odor | 1.9 mg/L | 2.0 mg/L + 10% | 0.05 mg/L | 97.4 | 0.05 mg/L | 97.4% |
To a capacity of 300 gallons (1.135 L).
* Note that while the testing was performed under standard labaratory conditions, actual performance may vary.
Application Guidelines / Water Supply Parameters
Water | pressure | 30 - 100 | psi !207 - 689 kPa) |
Water | temperature | 33°F - 100°F (0.6°C - 37.8°C) | |
Service flow | 0.5 gpm | (1.9 Ipm) |
To reduce the risk associated with ingestion of contaminants due to use with water that is
microbiologically unsafe or of unknown quality.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems must be installed and operated in accordance with manufacturer's recommended
procedures and guidelines.
[]CAUTION
To reduce the risk of property damage due to water leakage:
• Read and follow Use instructions before installation and use of this system.
•Install on COLD water lines only.
•Company with all state and local plumbing codes.
Never install or operate where inlet water pressure may exceed 125 psi (862 kPa).
•Protect filter from freezing. Remove filter in temperatures below 34°F (1°C).
•Replace cartridge at specified service interval. Cartridge MUST be replaced at least every 6 months.
•After replacing the water filter cartridge, dispense 2.5 gallons (9.46 liters) of water to purge the system, depressing and releasing the dispenser pad in cycles of 30 seconds ON and 60 seconds OFF. Discard the purged water.
To purchase a replacement filter, visit your local Sears store or call
Product distributed in the United States by Sears Brands Management Corporation, Hoffman Estates, IL 60179