Makita G1700i manual PRE-OPERATION Checks See Fig

Page 10

7. DC TERMINALS (See Fig. 2-t)

ENGLISH

DC electric power for battery charge is available.

- Red is positive (+) terminal.

 

 

- Black is negative (-) terminal.

8. DC CIRCUIT BREAKER (See Fig. 2-y)

DC circuit breakers shut off electric current when the current exceeds its limit or a malfunction occurs in the connected appliance.

Check for excessive current consumption or defects in the appliance. After making sure everything is in order, push the button to the " ON " position.

 

q BUTTON

e IN (ON)

FRANÇAISE

w KNOB

r OUT (OFF)

 

 

 

CAUTION

If circuit breaker continues to be activated,

discontinue use and check generator

and/or appliance for malfunction with

 

 

their respective service representatives.

 

Never interfere with the operation of the

 

circuit breaker knob or keep pushing it in

 

the "ON" position.

 

 

 

 

9. GROUND TERMINAL (See Fig. 2-i)

4.PRE-OPERATION CHECKS (See Fig. 3)

1. CHECK ENGINE OIL (See Fig. 3-q,w)

Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped.

Remove oil filler cap and check the engine oil level.

If oil level is below the lower level line, refill with suitable oil (see table) to upper level line. Do not screw in the oil filler cap when checking oil level.

Change oil if contaminated. (See "How-To" Maintenance.)

Oil capacity . . . . 0.4 liters (0.42 qts)

Recommended engine oil:

Use 4-stroke automotive detergent oil of API service class SE or higher grade (SG, SH or SJ is recommended). SAE 10W-30 or 10W-40 is recommended for general, all-temperature use. If single viscosity oil is used, select the appropriate viscosity for the average temperature in your area.

5W

10W

20W

Single grade #20

#30

#40

Terminal for grounding the generator.

Multigrade

10W-30

10W-40

ESPAÑOL

10. RECOIL STARTER (See Fig. 2-u)

Pull this handle to start the generator.

q RECOIL STARTER HANDLE

 

11. FUEL TANK CAP (See Fig. 2-o)

The fuel tank cap is located behind the cover. To open the cover, lift up with the dent portion depressed backward as shown in the illustration. Remove the fuel tank cap by turning counterclockwise.

q FUEL TANK CAP

w FUEL FILTER SCREEN e TANK CAP COVER

12. SIDE COVER (..) (See Fig. 2-!0)

To access the following items for servicing, take the applicable side cover out by removing the screw with screwdriver or coin.

LH-side cover ---- Air cleaner etc.

RH-side cover ---- Oil level gauge, Ignition coil,

Spark plug etc.

Ambient temperature

2. CHECK ENGINE FUEL (SeeFig. 2-o, 3-e)

WARNING

Do not refuel while smoking or near open flame or other such potential fire hazards. Otherwise fire accident may occur.

If fuel level is low, refill with unleaded automotive gasoline.

Fuel level should never over the RED marking at the inlet portion. (SeeFig. 3-e-q)

q RED MARKING

Be sure to use the fuel filter screen on the fuel filter neck.

q FUEL TANK CAP

w FUEL FILTER SCREEN e TANK CAP COVER

Fuel tank capacity . . . 3.5 liters (0.92 US.gal)

When using the generator first time or stopping due the fuel running out, pull the recoil handle several times after filling fuel up to the RED marking at the inlet portion of the fuel tank.

6

Image 10
Contents Generator 3ZZ9990147Over Federal Emissions Component Defect Warranty EnglishFactory Service Centers in Canada HOW to Make a ClaimContents ForewordSafety Precautions English FrançaiseEnglish Française COP Components See Fig Controls and Indicators See FigAC Receptacles PRE-OPERATION Checks See Fig Checking Component Parts Operating ProceduresSee Fig Starting the GeneratorG1700I 60Hz-120V Using Electric PowerAC Application See -r Connection of Cable Safety Precautions While ChargingDC Application See -t Stopping the GeneratorWattage Information Voltage Drop in Electric Extension CordsClean the spark arrester screen How to remove the spark arresterSpark Arrester Maintenance Schedule Periodic MaintenancePeriodic Maintenance Schedule table Maintenance ItemsServicing the AIR Cleaner See -w HOW-TO Maintenance See FigCleaning and Adjusting Spark Plug See -e,r Periodic Operation and InspectionTransporting Preparation for Storage See FigWhen Engine Fails to Start TroubleshootingWhen No Electricity Is Generated at Receptacle Specifications ModelWiring Diagram Inverter Engine Control UnitPage Makita Corporation
Related manuals
Manual 20 pages 13.72 Kb

G1700i specifications

The Makita G1700i is a powerful and versatile inverter generator that delivers reliable performance for both home and outdoor applications. With its compact design and advanced technology, it has quickly gained a reputation among users looking for a reliable source of portable power.

One of the standout features of the Makita G1700i is its impressive power output. It provides a maximum output of 1700 watts and a continuous output of 1400 watts, making it suitable for powering household appliances, recreational equipment, and tools. This generator is particularly valuable for camping trips, tailgating, and other outdoor activities, where access to electricity may be limited.

The G1700i is equipped with an advanced inverter technology that ensures clean, stable power. This is essential for sensitive electronic devices such as laptops, smartphones, and other gadgets, which can be damaged by unstable power supplies. The inverter technology also allows for efficient fuel consumption, giving users longer runtime on a single tank of fuel.

Another key characteristic of the Makita G1700i is its ultra-quiet operation. Producing only 58 decibels at rated load, this generator runs quietly enough to use in residential areas or during nighttime camping without disturbing the peace. The noise level is comparable to that of a normal conversation, making it an ideal choice for those who prioritize a quieter generator experience.

Mobility is also a highlight of the G1700i. Weighing in at just 39 pounds, it features a compact and lightweight design, complemented by an ergonomic handle for easy transportation. This makes it not only portable but also convenient for users who need to move it from one location to another.

Additionally, the Makita G1700i is designed with user safety and convenience in mind. It includes a variety of protective features such as overload protection, low oil shutdown, and a fuel gauge for easy monitoring. The generator’s easy-start recoil mechanism ensures that users can start it with minimal effort.

Overall, the Makita G1700i inverter generator stands out for its combination of power, efficiency, and quiet operation. Whether for home use, recreational activities, or emergency backup, it provides a dependable and portable power solution that meets a wide range of needs. Its advanced features and characteristics make it a top choice for anyone in need of reliable and efficient portable power.