Ingersoll-Rand LS150RLP-DP5M-F, HU40A, LS500RLP-E, Fulcrum Electric, FH2 Safe Operating Instructions

Page 5

SAFE OPERATING INSTRUCTIONS

The following warnings and operating instructions have been adapted in part from American Society of Mechanical Engineers (Safety) Standard ASME B30.7 and are intended to avoid unsafe operating practices which might lead to injury or property damage.

Ingersoll Rand recognizes that most companies who use winches have a safety program in force at their facility. In the event that some conflict exists between a rule set forth in this publication and a similar rule already set by an individual company, the more stringent of the two should take precedence.

Safe Operating Instructions are provided to make an operator aware of dangerous practices to avoid and are not necessarily limited to the following list. Refer to specific sections in the manual for additional safety information.

1.Only allow personnel trained in safety and operation of this product to operate and maintain this winch.

2.Only operate a winch if you are physically fit to do so.

3.When a “DO NOT OPERATE” sign is placed on winch, or controls, do not operate winch until sign has been removed by designated personnel.

4.Before each shift, check winch for wear and damage. Never use a winch that inspection indicates is worn or damaged.

5.Never lift a load greater than rated capacity of the winch. Refer to labels attached to winch or to “SPECIFICATIONS” section.

6.Keep hands, clothing, etc., clear of moving parts.

7.Never place your hand in the throat area of a hook or near wire rope spooling onto or off of winch drum.

8.Always rig loads properly and carefully.

9.Be certain the load is properly seated in saddle of hook. Do not support load on tip of hook.

10.Do not “side pull” or “yard”.

11.Always ensure that you, and all other people, are clear of the path of the load. Do not lift a load over people.

12.Never use the winch for lifting or lowering people, and never allow anyone to stand on a suspended load.

13.Ease slack out of wire rope when starting a lift or pull. Do not jerk the load.

14.Do not swing a suspended load.

15.Do not leave a suspended load unattended.

16.Never operate a winch with twisted, kinked or damaged wire rope.

17.Pay attention to the load at all times when operating the winch.

18.Never use the winch wire rope as a sling.

19.After use, or when in a non-operational mode, winch should be secured against unauthorized and unwarranted use.

WARNING LABEL

Each unit is shipped from the factory with warning label shown. If the label is not attached to your unit, order a new label and install it. Refer to the parts list for part number. Label is shown smaller than actual size.

(Dwg. 71060529)

4

Image 5
Contents Important Information Models FA2 and FA2.5 Page Safety Information Safe Operating Instructions Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Parts Ordering Information Limited Warranty
Related manuals
Manual 80 pages 57.07 Kb

LS150RLP, FA2B, FA10, FA2, FA5 specifications

The Ingersoll-Rand FA5 and FA5T are cutting-edge air compressor models designed to offer exceptional performance and reliability for a variety of industrial applications. With their robust engineering, these units are ideal for both small-scale and large-scale operations, providing a significant boost to operational efficiency.

One of the main features of the FA5 series is its advanced rotary screw design, which ensures a continuous supply of compressed air while minimizing energy consumption. This energy-efficient design not only reduces operational costs but also makes the models environmentally friendly. The FA5T variant introduces enhanced technology for higher performance, targeting industries that require a greater air flow.

The compressors are equipped with a state-of-the-art microprocessor controller that allows for precise monitoring of system performance. This intelligent controller provides real-time data on operating conditions, such as pressure levels and temperature, allowing operators to ensure optimal performance and preemptively address potential issues.

Another notable characteristic of the FA5 and FA5T is their quiet operation. These compressors incorporate sound-dampening technology, making them suitable for installation in noise-sensitive environments. The reduced noise levels help maintain a comfortable work atmosphere while also adhering to regulatory standards.

The FA5 series features durable construction with high-quality materials that enhance the longevity and reliability of the compressors. The robust design minimizes wear and tear, ensuring that the units remain operational even under demanding conditions. Additionally, maintenance is simplified, thanks to easily accessible components and straightforward service procedures, which help minimize downtime.

The FA5 and FA5T also offer flexibility in installation. Their compact design enables them to fit in limited spaces, making them ideal for various industrial settings. Users appreciate the versatility of these compressors, as they can be integrated into existing systems without significant modifications.

Ingersoll-Rand has incorporated innovative technologies into the FA5 and FA5T, such as variable speed drive capabilities which allow for greater control of output levels. This feature ensures that the compressor operates only as needed, further enhancing energy efficiency.

Overall, the Ingersoll-Rand FA5 and FA5T represent a perfect balance of high performance, energy efficiency, and operational reliability. Their advanced features make them a top choice for industries looking to improve productivity while reducing environmental impact.