Ingersoll-Rand manual Parts List / 651747-X-B

Page 3

PARTS LIST / 651747-X-B

15

13 9, 8 D

14

11, 12

10

17 18

A

1

3

B

2 H

 

 

 

 

 

 

36

 

 

 

 

5

 

 

 

 

6

 

 

 

 

35

A

 

 

B

7

 

 

 

20

 

19 V

 

 

ITEM DESCRIPTION (Size in inches)

:1 14 Gauge Wire (12" long, black)

2 Cap Screw (3/8" / 16 x 7/8")

:3 14 Gauge Wire (12" long, red)

4Machine Screw (#10 / 24 x 1/4")

5 Ring Terminal

:6 14 Gauge Wire (7" long, green)

7 Pipe Plug (1/2 / 14 P.T.F.)

8 Machine Screw (#6 / 32 x 5/8")

9Nut (#6 / 32)

10

Terminal Block

11

Lockwasher (#6)

12

Machine Screw (#6 / 32 x 1/4")

13

Mounting Plate

14

Thermometer (0_ / 250_ F)

15

Site Ring

QTY

(1)

(6)

(1)

(1)

(1)

(1)

(1)

(4)

(4)

(2)

(4)

(4)

(1)

(1)

(1)

PART NO.

78140/XXX/X

Y99/678

78141/XXX/X

Y76/103/C

78143

78142/XXX/X

Y227/5/L

Y8/468/C

Y22/6/C

92932

Y1/6

Y8/463/C

93583/1

91696

93588/1

16

16 Retaining Ring

(1)

29664

29

28

27 H 26

22

``B"

4

21

1/11/16"

(42.9 mm)

Mounting Holes (2)

5/16 ￿ 18 UNC ￿2B 1/2" (12.7 mm) deep

17Adjusting Knob

18Screw

19Cap

20Cover

21Housing

22Fluid Track

23Cutoff Assembly

24Heater Cartridge Assembly (+10% / /5%)

651747/1/B (120 volt AC, 6.84 Ohms)

651747/2/B (230 / 240 volt AC, 27.36 Ohms)

651747/3/B (415 / 440 volt AC, 91.96 Ohms)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

93586/1

93585/1

93584/1

93587/1

93590/1

92974

66834/1

66751/1

66751/2

66751/3

23

`

(ref.) 1

5

 

(ref.) 3

6

 

7

(ref.) 6

8

 

View B / B

25Pipe Plug (1/2 / 14 N.P.T.)

26Cap Screw (3/8" / 16 x 1/1/4")

27Retaining Ring

28Indicator Lamp models 651747/1/B (120 volt AC) models 651747/2/B (220 volt AC) models 651747/3/B (440 volt AC)

(1)

(3)

(1)

(1)

(1)

(1)

Y17/53

Y99/63

93589/1

93591/1

93591/3

93591/5

s24

``C"

25

 

 

 

29

Thermostat (60_ / 250_ F) (20 amp. / 480 volt AC)

32

 

 

30

Terminal

31

 

33

: 31

14 Gauge Wire (6" long, black)

 

 

 

 

1

 

32

Terminal

30

 

 

2

 

33

Terminal

 

3

 

 

 

 

 

 

4

34

34

Terminal

 

 

35

Label

 

 

 

 

View A / A

 

36

Mounting Plate

:Available in bulk rolls only.

(1)

(5)

(2)

(2)

(2)

(2)

(1)

(1)

92972

78035

78140/XXX/X

78143

78034/1

78031

91081

95634

FIGURE 2

``B" Outlet (1/2 ￿ 14 N.P.T.F. ￿ 1) ``C" Inlet (1/2 ￿ 14 N.P.T.F. ￿ 1)

H(2 and 26) Torque to 10 / 12 ft lbs (13.6 / 16.3 Nm). D (8) Apply Loctite 242 to threads.

V (19) Apply Nickel anti/seize to threads. s (24) Apply Watt Lube.

` Apply Dow Corning 340 Silicone Heat Sink Compound.

(24) Heater Cartridge

(6) Green

8

4

7

3

 

(3) Red

6

2

Input Line

(1) Black

5

1

FIGURE 3

(28)Indicator Lamp

(23)Cutoff Assembly

(29)Thermostat

Wiring Schematic

651747/X/B

PAGE 3 OF 4

Image 3
Contents Fluid Heater Data Typical InstallationDimensional Data Operating PrecautionsReassembly Power Supply and InstallationMaintenance DisassemblyParts List / 651747-X-B Accessories Trouble Shooting

651747-X-B specifications

The Ingersoll-Rand 651747-X-B is a robust and highly efficient air compressor designed for various industrial applications. Known for its reliability and performance, this model stands out due to its advanced technologies and user-friendly features.

One of the key features of the Ingersoll-Rand 651747-X-B is its powerful, electric-driven compressor system. This ensures consistent airflow and pressure, making it ideal for demanding tasks in construction, automotive, and manufacturing sectors. The compressor is engineered to deliver optimal performance while minimizing energy consumption, which not only reduces operating costs but also enhances sustainability.

The 651747-X-B is equipped with a durable and high-quality construction that withstands the rigors of everyday use. Its heavy-duty components are designed to endure tough working conditions, providing extended service life and reducing the frequency of maintenance needs. This model's robust design is complemented by an efficient cooling system, which prevents overheating and ensures the compressor operates at peak efficiency.

Another notable characteristic of the Ingersoll-Rand 651747-X-B is its advanced control technology. The compressor features a user-friendly interface that allows operators to easily monitor and adjust settings in real time, promoting operational efficiency and safety. This technology enables automatic start-stop operations, which further conserves energy and enhances user convenience.

Moreover, the 651747-X-B incorporates noise-reducing technologies to operate quietly, making it suitable for environments where noise levels need to be kept to a minimum. The sound insulation features help create a more pleasant work atmosphere while complying with regulatory noise standards.

Maintenance is simplified with the Ingersoll-Rand 651747-X-B. Its design includes easy access to key components, making routine checks and servicing straightforward. This feature is vital for businesses aiming to minimize downtime and maximize productivity.

In summary, the Ingersoll-Rand 651747-X-B is a highly efficient air compressor that combines durability, performance, and user-friendly technology. With its robust construction, advanced control systems, energy-efficient operations, and lower noise levels, it is an excellent choice for various demanding industrial applications, ensuring reliability and integrity in every operation.