13. Faults
Fault | Possible Cause | Remedy | |
|
|
| |
Not able to open the | Battery power too low. | Insert a new | |
Water Timer using |
| alkaline battery. | |
the “man On/Off” |
|
| |
Tap turned off. | Turn on tap. | ||
function. | |||
|
| ||
|
|
| |
Watering not | Battery power too low. | Insert a new | |
initiated. |
| alkaline battery. | |
|
|
| |
| Data input / changes | Input data or make | |
| made while the pro- | changes before or | |
| gram was starting or | after the starting times | |
| immediately before. | you have chosen. | |
|
|
| |
| Tap turned off. | Turn on tap. | |
|
|
| |
| Soil Moisture Sensor | If dry, check setting/ | |
| or Rain Sensor indi- | position of the Soil | |
| cate sufficient moisture. | Moisture Sensor or | |
|
| Rain Sensor. | |
|
|
| |
Battery flat after | Not an alkaline | Use an alkaline | |
working for a | battery. | battery. | |
short time. |
|
| |
|
|
|
If you have any problems with your Water Timer Electronic, please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet.
We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories.
EU Certificate of Conformity
The undersigned
GARDENA Kress + Kastner GmbH ·
hereby certifies that, when leaving our factory, the unit indicated below is in accordance with the harmonised EU guidelines, EU standards of safety and product specific standards.
This certificate becomes void if the unit is modified without our approval.
Description of the unit: | Year of CE marking: | |
Water Timer Electronic | 1998 | |
Type: T14 | Ulm, 17.07.1998 | |
Art. No.: 1800 | ||
| ||
EU directives: |
| |
Electromagnetic Compatibility |
| |
89/336/EC | Thomas Heinl | |
Directive 93/68/EC | ||
Technical Dept. Manager | ||
|