AC VOLTAGE, INSTALLATION AND RACK MOUNTING | 3 |
115v - 230v AC Voltage Selector Switch
This switch is found on the chassis rear panel. The 115V position of this switch is correct for North America; most other regions require setting it to 230V. Make sure the 115/230V switch is set for the correct AC line (mains) voltage before you connect the Model 275’s power cord and before you install it. The unit may be seriously damaged if this switch is set incorrectly.
Protective Cover
Load
Impedance
AC
Voltage
115V 230V 60Hz 50Hz
AC 115V/60Hz AC 230V/50Hz
Power Consumption: 350W
Installation and Ventilation Requirements
Install your Model 275 away from heat sources such as heating ducts, radiators, or other heat producing components. Always position it horizontally.
Observe the following ventilation guidelines when installing the Model 275 in an equipment rack or any other enclosed space:
You should never install the Model 275 in an unventilated equipment cabinet or compartment because hot air will not exhaust adequately to prevent overheating. Air won’t often circulate adequately in a cabinet or enclosure whose front and back sides are open; pockets of intense heat can still develop around any
Do not place the unit on carpeting or any other material that could obstruct air flow into the ventilation holes in its chassis bottom.
Rack Mounting
The Model 275 front panel occupies only one rack space in a standard 19” equipment rack.
For rack mounting, you’ll need to use the Parasound RMK11 rack mounting kit (purchased separately). We recommend that you use the 8 insulated shoulder washers with the four mounting bolts which are included with the RMK11. Position these washers on both sides so they “sandwich” the front panel before the mounting bolts are screwed into the rack rail. This will eliminate