Blade Guard (Figure 6A & 6B) | 6A | |
Wait for blade to come to complete stop! | ||
|
UNPLUG TOOL!
The guard swings open for cleaning inside of blade housing or for changing
blades. To open guard turn the guard release knob clockwise (facing blade
guard side of tool) until it stops (a turn of about 90˚) fig. 6A detail; pull the knob to open the door (fig. 6B). When closing the guard turn the knob clockwise 90˚ (fig. 6A detail) and push the door completely closed. The knob should automatically
lock the door. If the knob doesn’t return to 6B the locked position press the door until
the knob engages.
BE SURE GUARD IS PROPERLY
CLOSED AND KNOB IS LOCKING IT
BEFORE OPERATING EDGER.
Attaching The Blade (Figure 7)
Wait for blade to come to complete stop! | 7A |
UNPLUG TOOL!
The blade, two spacers and hex head nut with conical washer should be attached to your edger in the order shown. Please check that the blade has been properly mounted before using your edger. The Edger blade has two wear indicators that show when blade needs to be replaced. When the blade wears to the small hole at each end of the blade it will give only 1/4" depth of cut and should be replaced.
Tip: To increase blade life, keep initial cutting depth at minimum and increase depth setting as blade wears.
To Remove The Blade For | 7B | |
Replacement: | ||
| ||
Wait for blade to come to complete stop! |
| |
UNPLUG TOOL! |
| |
CAUTION: Blade rotates momentarily |
| |
after the switch is released. |
| |
1. Turn knob and open guard door. (Fig. 7A) |
| |
2. Loosen the hex head nut (9/16”). Use |
| |
a 1" wrench on the outer spacer, or a |
| |
2” x 4” wood block between the |
| |
blade and guard if necessary to hold |
| |
the blade from turning. (Fig. 7B) |
|
6