Nilfisk-ALTO EQU Installation & Connection, Mains Connection, Ground lift switch, AC Inlet

Page 9

NOTE : While you can use any input connector with any output connector, only one set of these con- nectors is to be used at one time, detail wiring and connection, please refer to 4.2 audio connection.

18. Ground lift switch

This switch is used to disconnect the signal ground from the mains and chassis earth. If it is determined that the equalizer is the cause of hum or buzz in your system due to a ground loop, move this switch to the "lift" position.

19. Fuse holder / Voltage selector

This is a dual voltage unit. Before you attempt to connect and operate the unit, please make sure that your local voltage matches the voltage on the fuse-holder cover.

Caution: The fuse protecting the AC supplies circuits of this unit. The fuse can only be changed by a qualified technician, in the event of a fault or changing the supply voltage. If the fuse continues to blow after replacing, discontinue use of this unit before repaired.

120V-110

240V-220

 

 

 

220-240V

 

 

 

110-120V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS IS SET FOR 110V AC TO 120V AC OPERATION

THIS IS SET FOR 220V AC TO 240V AC OPERATION

The fuse-holder above the AC connector on the rear of the chassis has 3 triangular markers(please refer to the above pictures), with two of these triangles opposing each other, your unit is set to the operating voltage printed next to these markers.

To change, pull fuse-holder out and rotate 180,then push in again.

20. AC Inlet

This connector is meant for the connection of the supplied main cord.

Do not insert power cable into unit until voltage has been correctly set. Do not plug power cable into AC power until voltage has been correctly set.

4. INSTALLATION & CONNECTION

4.1 Mains Connection

Please ensure that the EQU Series Graphic Equalizer is set to the correct supply voltage before plugging the power cord into the wall outlet , use the same fuse as marked on the fuse holder at the AC power connection socket.

The mains connection of the EQU Series Graphic Equalizer is made by using the enclosed mains cable and a standard IEC receptacle. It meets all of the international safety certification requirements.

4.2Audio Connection

The EQU Series Graphic Equalizer presents with balanced XLR & 1/4" TRS and unbalanced RCA connectors, and it can be interfaced by several ways to support a variety of applications without any signal loss. The EQU Series Graphic Equalizer can be used on a single instrument by connecting to a mixing console's main inserts, or on an entire mix "in-line" between a mixing console's outputs and a power amplifier.

- Wiring Configuration

Either the 1/4" TRS phone jack or the XLR connector can be wired in balanced and unbalanced modes, which will be determined by the actual application status, please wire your system as the following wiring examples:

1/4"TRS jack

1/4"TRS jack

XLR Unbalanced Input XLR Balanced Input

Unbalanced Input

Balanced Input

 

8

Image 9
Contents EQU Series 15/31 Band Graphic Equalizer Important Safety Instructions Safety Related SymbolsPreface Front Panel Rear Panel Table of ContentIntroduction Feature ListControl Elements Front PanelEQU231VU Front Panel EQU131VU Front PanelEQU231LED Front Panel EQU231TWIN Front PanelRear Panel XLR input and output connector 16 /4 TRS phone plug input and output connectorEQU131VU Rear Panel Ground lift switch Installation & ConnectionMains Connection Fuse holder / Voltage selectorLine Connection Rack MountingUnbalanced Insert Points ConnectionApplication Sound FrequencyTypical Frequency of Each Instrument and Voice Equalizer In Sound Reinforcement Systems Line InstrumentMixing Console Band 1/3 octave , ISO spacing 2H series Technical SpecificationsEQU231VU / 231LED Band 1/3 octave , ISO spacing 2H series Band 1/3 octave , ISO spacing 4H seriesWarranty Registration Card Warranty