MOUNTING AND WIRING INSTRUCTIONS
CAUTION: For fixtures labeled for outdoor and wet location use, provide a
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.
1.Turn off power at circuit box to avoid possible electric shock.
2.Thread nipple (A) into center hole on mounting bar (B) approximately 3/4 inch (see fig. 1).
3.Secure lockwasher (C) and nut (D) to nipple (A) on back side of mounting bar (B).
4.Secure mounting bar (B) to outlet box (E) with outlet box screws (F) (not included).
5.Identify color coding of fixture wires (see figure 2 on page 11).
6.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.
7.Fit wire connector (G from fig. 1) over wires and twist until there is a firm connection. If wire connector (G) easily comes off, reattach and check again for a firm connection (see fig. 1).
8.Repeat steps 6 and 7with the white (group B from fig. 2) fixture and outlet box wires.
9.Partially thread green grounding screw (H) into side hole (I) on mounting bar (B) (see fig. 1).
10.Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box
(E) around green grounding screw (H) on mounting bar (B).
11.Tighten green grounding screw (H). Do not over tighten.
12.Tuckwires inside outlet box (E).
FIXTURE ASSEMBLY INSTRUCTIONS
1.Place canopy (J) over outlet box (E) with nipple (A) protruding through center hole of canopy
(J)(see fig. 1).
2.Secure into place with washer (K) and cap nut (L).
3.Install lamp(s). Do not exceed recommended wattage.
4.Place glass lens (M) over canopy (J).
5.Place wire frame (N) over glass lens (M) and secure with screw (O).
6.Turn power back on at circuit box.
4