OPERATING INSTRUCTIONS

3.If leak is detected at regulator/cylinder valve connection, disconnect, reconnect, and perform another leak check. If you continue to see bubbles after several attempts, cylinder valve is defective. Call our customer service hotline at 1-866-985-7877, 9 a.m. – 6 p.m., EST, Monday – Friday

IF NO BUBBLES APPEAR AT ANY CONNECTION, THE CONNECTIONS ARE SECURE.

Note: Whenever gas connections are loosened or removed, you must perform a complete leak check.

Caution: Do not attempt to operate this appliance until you have read and understand all Safety Information in this manual and all assembly is complete and leak checks have been performed.

Before Turning Gas Supply ON:

1.Your heater was designed and approved for OUTDOOR use only. Do NOT use it inside a building, garage, or any other enclosed area.

2.Make sure surrounding areas are free of combustible materials, gasoline, and other flammable vapors or liquids.

3.Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there are no leaks.

4.Be sure the cylinder cover is clear of debris. Be sure any component removed during assembly or servicing is replaced and fastened prior to starting.

Before Lighting:

1.Heater should be thoroughly inspected before each use, and by a qualified service person at least annually. If re-lighting a hot heater, always wait at least 5 minutes.

2.Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas should be leak tested. If the hose leaks, it must be replaced prior to operation. Only use the replacement hose assembly specified by the manufacturer.

Lighting:

NOTE: For initial start or after any cylinder change, hold the control knob in for 2 minutes to purge air from all gas lines before proceeding.

1.Turn the control knob to the “OFF” position.

2.Fully open the LP cylinder valve.

3.Turn the control knob half way between the small flame and the large flame symbols.

4.Push control knob in and then push the RED igniter button to ignite the main burner. Repeat until the burner ignites. Keep the control knob fully pushed in for an additional 30 seconds after the burner ignites, then release the control knob.

5.To increase the flame, turn the control knob clockwise toward the large flame symbol. To decrease the flame, turn the control know counter clockwise towards the small flame symbol.

6.To turn the appliance OFF, push down the Control knob and turn clockwise to the OFF position.

7.Wait at least 5 minutes before attempting to re-light the heater.

8.Turn the gas cylinder valve to OFF or closed.

If you experience any ignition problems, please consult “Troubleshooting” on page 13.

Caution: Avoid inhaling fumes emitted from the heater’s first use. Smoke and odor from the burning of oils used in the manufacturing will appear. Both smoke and odor will dissipate after approximately 30 minutes. The heater should NOT produce thick black smoke.

-10 -

Image 10
Contents Model # LIP-10A-TGG-LPG-SP Item # 60788,60368,60485 Attach Your Receipt HerePackage Contents Hardware Contents Safety Information Assembly Tools Required for Assembly not includedAssembly Hint Control knob should be above decal on post Assembly Operating Instructions Leak CheckBefore Lighting Before Turning Gas Supply onLighting Re-Lighting When Heater is onOperation Checklist Shut DownCare and Maintenance TIP for Stainless Steel ModelsProblem Possible Cause Corrective Action TroubleshootingDistributed By Important Notice