Receiver Operation:
Battery Test
Indcator
Battery ![]()
Level Mark ![]()
![]()
![]()
![]()
![]()
Receiver Front Panel
DynatelTM
2210 |
|
577 Hz | 33 KHz |
On
Off |
|
| Hz |
Gain Adjust | Depth | Freq |
1.Press ![]()
![]()
![]()
![]()
![]()
to turn receiver on and see battery level. Hold down ![]()
![]()
![]()
![]()
![]()
for continuous Battery Test. If bar graph is to the left of the battery level mark, replace batteries. Note: when
batteries are low, the battery test indicator
remains on.
2.Press
to match Frequency to transmitter output or select ![]()
![]()
for passive power locating.
3.Press
to set Gain when bar graph is not visible or is closed. For High Volume (
),
hold down
while turning unit on. To return to normal volume, turn unit off, then on again.
4.Make broad sweeps with receiver handle in line with target cable path to get maximum bar graph closure; press
. Maximum bar graph and numeric indication occurs directly over cable.
5.Place the receiver upright on the surface directly over cable. With handle parallel to
path, press
to display estimated Depth. Press again to display numeric Current ![]()
indication. Cable with highest current indication is the target. Press
to return to trace mode, and press
. Unit returns to trace mode automatically after eight seconds.
Note: Active Duct Probe (sonde) depth will differ from cable depth due to the shape of the electromagnetic field of the ADP. Conversion tables are provided with the ADP to obtain accurate depth estimates.